Threaded Connectors
Teon tape should be used with threaded
SharkBite connectors to make a proper
seal.
Galvanized Tubing
SharkBite Universal ttings should not be
installed (threaded or push-to-connect)
on galvanized tubing.
SharkBite Soldering
When soldering is required near a
SharkBite Universal connection, make
all solder joints rst and then make the
SharkBite connections. Flame can cause
the pipe to reach high temperatures and
should not be used close to a SharkBite
Universal tting.
Sharkbite Fitting Reuse
SharkBite Universal ttings are intended
to be a permanent connection and are
not designed for repeated connection and
disconnection. If the need arises to change
a tting aer initial installation this can
be done given that proper care is taken
when removing and reinstalling SharkBite
Universal ttings.
SharkBite disconnect tongs or SharkBite
disconnect clips must be used when
removing the ttings.
The initial pipe and the new pipe must be
clean and free from scratches and burrs.
Mark the correct insertion depth, insert the
tting to the mark, turn the water back on
and check for leaks.
Working Pressure and
Temperature
SharkBite Universal ttings have a
maximum temperature of 200°F
maximum pressure 200 psi when used on
copper pipe. When used on PVC, CPVC,
PEX, PE-RT or HDPE refer to the maximum
pressure temperature rating of the pipe.
PEX Stieners
SharkBite Universal ttings (3/8" to 1")
come with an Integral PEX Stiener. 1/4"
(3/8" OD) ttings do not require PEX
stieners. PEX Stiener are required for
PEX, PE-RT and HDPE pipe. 2XL PEX
Stieners sold separately.