Installation Guide

INSTALLATION INSTRUCTIONS
SPECIFICATIONS
WARNINGS & PRECAUTIONS
Make a clean square cut on tubing to be
inserted into fitting.
Remove any obstructions before
inserting tube into fitting. Make sure the
tube is fully inserted into the fitting.
Before disassembling ensure that water
supply is o and pressure is eliminated.
To disassemble push the collar in the
direction of the fitting and then pull the
tube out.
Fittings are not recommended for use with liquids
other than water and food or beverage products.
Where fittings may be used with other chemicals
contact RWC for advice.
Do not use pipe dope or other liquid thread sealers.
Use only teflon tape to seal threaded connections.
If your plumbed line is used as an electrical ground,
you must use a jumper wire to provide continuity
across plastic fittings and tubing.
When tightening threaded fittings, use care not to
over-torque the fitting as this may damage the
fitting and cause a leak or other failure.
Material: Acetal POM
Ratings: FDA, ANSI/NSF 51, 61
Pressure and Temperature:
1/4", 5/16", 3/18", 1/2" OD Fittings:
150 PSI Max at 73˚F
60 PSI Max at 150˚F
Approved Pipe Types: Polyethylene, Nylon, PEX,
Soft Copper (must be round and in good condition)
Warranty: One (1) year warranty from date of purchase
I0550 Rev. New
Pipe
Insertion
Depth
To ensure proper connection has been
made pull the tubing once.
SIZE
1/4" OD
0.65"
0.77"
0.90"
1/2" OD
3/8" OD
INSERTION DEPTH