Install Instructions

6
0025 ft CASH ACME 02 BARRIER
1/2” SDR9 PEX5006 160PSI@73F - 100PSI@180F C1 WG 6.12.14=16:00
CSA B137.5 ANSI/AWWA C904 ASTM F876/877 (ASTM F1807, ASTM F2098, ASSE1061)
CODE EVALUATION
TUBING LENGTH
TUBING SIZE & IDENTIFICATION
MANUFACTURING LOCATION & DATE
MANUFACTURER
OPTIONAL FOR OXYGEN BARRIER PIPE ONLY
SharkBite
®
PEX Pipe must be properly supported to protect against excessive strain. For both vertical
and horizontal applications we recommend the pipe be supported every 32" between supports
(sizes 1" and smaller), leaving a little slack (1/8"-1/4") in the pipe to allow for normal expansion
and contraction. Always use approved PEX supports and never use a support that has sharp edges.
The SharkBite PEX Pipe can be submerged in concrete but we recommend following these guidelines to ensure a long lasting, maintenance-
free installation.
All SharkBite PEX Pipe is marked with:
Cross linking is a process that changes the chemical structure of high
density polyethylene used to make PEX Pipe, so that the polymer
chains are connected with each other in a three-dimensional matrix
by chemical bonds. PEX A, B and C are terms used to describe the
dierent manufacturing methods used to produce PEX Pipe, not
grades of PEX. Regardless of which manufacturing method is used,
all PEX Pipe meets the same ASTM standards for commercial and
residential plumbing applications.
Classification of Crosslinked Polyethylene
Typology Method Symbol
A Chemical Peroxide cross linking PEX-a
B Chemical Silane cross linking PEX-b
C Physical Radiation cross linking (beta) PEX-c
D Chemical Azocomponents cross linking PEX-d
SHARKBITE PEX PIPE MARKING:
PROPER SUPPORT OF SHARKBITE
®
PEX PIPE
CONCRETE INSTALLATION OF SHARKBITE
®
PEX PIPE
TECHNICAL DATA FOR SHARKBITE
®
PEX PIPE
CROSS LINKING METHODS
Do not allow joints within the slab. Use a continuous
length of SharkBite PEX Pipe within the slab and be sure
to check for leaks before pouring concrete.
Protect the SharkBite PEX Pipe with non-metallic
sleeves when entering or exiting the concrete slab.
A larger diameter piece of SharkBite PEX Pipe also
works well in this application.
CHLORINE RESISTANCE