SharkBite New Construction System Installation Guide ® INCLUDING ® ® SharkBite EvoPEX Fittings SharkBite Universal Fittings SharkBite Integral Valves SharkBite PEX Pipe An Evolutionary PEX Push System EvoPEX_Installation Instructions_2018_FINAL.
Table of Contents INTRODUCTION Features and Benefits of SharkBite EvoPEX Fittings Features and Benefits of SharkBite Universal Fittings ® ® 3 MAKING A SHARKBITE EVOPEX CONNECTION 4 MAKING A SHARKBITE UNIVERSAL CONNECTION 5 SHARKBITE PEX PIPE 6 TECHNICAL DATA 6 FREQUENTLY ASKED QUESTIONS (FAQS) 8 INSTALLATION REQUIREMENTS 10 WARRANTY 12 ® ® Connection with SharkBite PEX Connection with SharkBite PEX Proper Support Concrete Installation Cross Linking Methods SharkBite PEX Pipe Marking
INTRODUCTION Introduction The purpose of this guide is to familiarize plumbing professionals with the ® SharkBite Connection System, and the recommended method of installing ® ® the SharkBite EvoPEX system, SharkBite Universal brass push-to-connect fittings, and SharkBite PEX Pipe. SharkBite EvoPEX fittings and SharkBite Universal brass fittings are for use in hot and cold domestic water, and radiant heating/cooling systems.
Making a SharkBite EvoPEX Connection STEP 1 When cutting SharkBite PEX Pipe, ensure that the ends are cut square and the surface is smooth. Ensure that both the EvoPEX pipe and fitting are clean and free of dirt and debris in preparation for making a connection. STEP 2 Push the pipe into the fitting firmly (a twisting action reduces insertion force). Take care to avoid inserting the pipe at an angle.
® Universal Connection Making a SharkBite MAKING A SHARKBITE UNIVERSAL CONNECTION STEP 1 When cutting SharkBite PEX Pipe, ensure that the ends are cut square and the surface is smooth. Ensure that both the PEX pipe and fitting are clean and free of dirt and debris in preparation for making a connection. STEP 2 Insert the pipe through the release collar to rest against the grab ring. STEP 3 Push the pipe firmly with a slight twisting action until it reaches the tube stop.
PROPER SUPPORT OF SHARKBITE PEX PIPE SharkBite PEX Pipe must be properly supported to protect against excessive strain. For both vertical and horizontal applications we recommend the pipe be supported every 32" between supports (sizes 1" and smaller), leaving a little slack (1/8"-1/4") in the pipe to allow for normal expansion and contraction. Always use approved PEX supports and never use a support that has sharp edges.
TECHNICAL DATA FOR SHARKBITE PEX PIPE (CONT’D) CERTIFICATIONS: PRESSURE LOSS DATA: The SharkBite PEX Pipe is design certified to ASTM F-876, F-877, UL 1821, CSA B137.5 standards, and is listed to the NSF standards 14 and CSA B137.5 standards for use in potable water systems. Pressure Loss psi/100 ft of pipe Flow Rate GPM 3/8" 1/2" 3/4" 1" 0.2 0.427 0.099 0.019 0.006 0.3 0.880 0.204 0.039 0.012 0.4 1.470 0.341 0.065 0.019 0.5 2.189 0.508 0.097 0.029 0.6 3.032 0.703 0.135 0.
Frequently Asked Questions (FAQs) SharkBite EvoPEX Q. Why are SharkBite EvoPEX push-to-connect fittings recommended to be used only with SharkBite PEX Pipe while SharkBite Universal brass fittings are recommended to be Q. How well do SharkBite joints hold up in freezing temperatures? A. SharkBite PEX water systems are less susceptible to burst in used with any manufacturers PEX Pipe that meets ASTM freezing conditions due to the pipe’s ability to expand.
Frequently Asked Questions (FAQs) ® MAKING A SHARKBITE UNIVERSAL CONNECTION SharkBite EvoPEX Q. Are SharkBite EvoPEX fittings, SharkBite Universal brass fittings, and SharkBite PEX Pipe UV resistant? A. SharkBite Universal brass fittings can be used in sunlight Q. Can SharkBite PEX Pipe be installed to a water heater? A. SharkBite PEX Pipe should not be installed closer than 18" of the water heater unless specified otherwise by local when installed on copper or CPVC. SharkBite PEX Pipe and code.
Installation Requirements SharkBite Burial SharkBite Universal fittings are suitable for burial in most applications; however care is required when using fittings in applications that require burial to ensure the correct installation practices are used and due care is given to any environmental factors that may have a detrimental effect on the life expectancy of the fittings and pipe.
Installation Requirements MAKING A SHARKBITE® UNIVERSAL CONNECTION SharkBite Fitting Reuse SharkBite Universal fittings are intended to be a permanent connection and are not designed for repeated connection and disconnection. If the need arises to change a fitting after initial installation this can be done given that proper care is taken when removing and reinstalling SharkBite Universal fittings.
Reliance Worldwide Corporation 2727 Paces Ferry Road Phone: 1-877-700-4242 • Fax: 1-877-700-4280 www.rwc.com Building Two Suite 1800 Atlanta, GA 30339 Reliance Worldwide Corporation (Canada) Inc. 74 Alex Avenue Vaughan, Ontario, L4L 5X1 Phone: 1-888-820-0120 Sales Inquiries: canadasales@rwc.com Orders: canadaorders@rwc.com Tel: 1-877-700-4242 Fax: 1-877-700-4280 www.SharkBite.com www.sharkbite.com www.cashacme.