Service manual

16
20U-FS1
CU20FS1
16-1
16-2
ADJUSTMENT
ITEM
ADJUSTMENT
POSITION
CONTROL
PRE-ADJUST
REQUIREMENT
CONTENT
INPUT
CONDITION
OUTPUT
ADJUSTMENT
PROCEDURE
BUS OPTION FOR THIRD STAGE SERVICE DATA
FUNCTION
001 002 003 004 005 006 007 008 009 010
DEMO DOWNLOAD V-CHIP SP FAO P.PREF UNIV+ VIEW EZ PON-CH
14UFM1 1 1 1 0 0 0 0 1 0 0
CU14FM1 1 0 0 0 0 0 0 1 0 0
20U-FS1 1 1 1 1 1 1 1 1 0 0
CU20FS1 1 0 0 1 1 1 1 1 0 0
DEF “0”=DISABLE “1”=ENABLE
009 “0”=EZ-SETUP “1”=AUTO PRESET
BUS OPTION FOR THIRD STAGE SERVICE DATA
FUNCTION
011 012 013 014 015 016 017 018 019 020
FAV-COL COMP AV AV2 MTS TONE AUTO LAN SETUP AV-FR
14UFM1 1 0 1 0 0 0 0 0 1 3
CU14FM1 1 0 1 0 0 0 0 0 1 3
20U-FS1 1 1 1 1 1 1 0 0 1 3
CU20FS1 1 1 1 1 1 1 0 0 1 3
DEF 011 ”0”=FAV-COL “1”=COL-TEMP
018 “0”=ENGLISH “1”=SPANISH
019 “0”=NO SET UP “1”=AUTO SETUP
OPTION SET UP
REFER AS BELOW STEP RANGE REFER AS BELOW
14UFM1
OSD CHECKING
ADJUSTMENT
ITEM
ADJUSTMENT
POSITION
CONTROL
PRE-ADJUST
REQUIREMENT
CONTENT
INPUT
CONDITION
OUTPUT
ADJUSTMENT
PROCEDURE
DATA SETUP FOR FIRST AND SECOND STAGE SERVICE DATA
FUNCTION
V05 F13 F14 F16 F17 F30 F34 F38 F40 F49
SHARP Y-DL(TV) Y-DL(AV) TINT-AV COL-AV 1W(AV) SL(TV) VD(TV) AS(TV) CP
14UFM1 50 5 2 8 4 1 1 1 1 1
CU14FM1 50 5 2 8 4 1 1 1 1 1
20U-FS1 50 5 2 8 4 1 1 1 1 1
CU20FS1 50 5 2 8 4 1 1 1 1 1
DEF
DATA SETUP FOR FIRST AND SECOND STAGE SERVICE DATA
FUNCTION
F18 F19 F20 F21 F22 F23 F52 F53 F35 F41 F48
R-D(R2) R-D(R) R-D(B) B-D(R2) B-D(R) B-D(B) C-OF TI-OF SL(AV) AS(AV) FAO-VOL
14UFM1 +8 +3 -2 -18 -8 +6 0 +8 1 1 60
CU14FM1 +8 +3 -2 -18 -8 +6 0 +8 1 1 60
20U-FS1 +8 +3 -2 -18 -8 +6 0 +8 1 1 58
CU20FS1 +8 +3 -2 -18 -8 +6 0 +8 1 1 58
DEF
OPTION SET UP
REFER AS BELOW STEP RANGE REFER AS BELOW
14UFM1
OSD CHECKING