Service manual

21G-FX10L
4 – 2
AUTO ADJUSTMENT
H-VCO
RF-AGC
PIF-VCO
1. When there is H-VCO auto adjustment key input at item
H-VCO, auto adjustment will be implemented.
2. H-FREE (1chip) is set to 1.
3. H-OUT (1chip) is set by intelligent monitor output.
4. IM input becomes TIM input.
5. H-VCO (1chip) data is changed so that the number is 126 inside 8ms interval.
6. When adjustment is completed, OSD display and H-VCO auto adjustment data of EERPOM are updated.
7. H-FREE
(
1chip
)
, intelli
g
ent m onitor output, IM input mode are recovered.
1. If there is RF-AGC auto adjustment key input at item RF-AGC, auto adjustment will be implemented.
2. AGC-OUT (MONITOR(1chip)is set by intelligent monitor output.
3. IM input becomes AD input.
4. RF-AGC(1chip) is decreased from current RF-AGC value to 0, the maximum AFT input voltage is obtained.
5. RF-AGC(1chip) is increased until at the point of AFT input voltage is (max. 0.3V), adjustment is completed.
6. When adjustment is completed, OSD display and RFGC auto a djustment status in EEPRO M are updated.
7. Intelli
g
ent monitor output, IM input mode are recovered.
1. If there is PIF-VCO auto adjustment k ey input at item PIF- VCO, auto adjustment will be implemented.
2. VIF-DEF (1chip) is set to 1.
3. AFT output (1chip) is set by intelligent monitor output.
4. IM input becomes AD input.
5. VIF-VCO (1chip) is changed so the input voltage becomes 2.5V.
6. When adjustment is completed, OSD display and PIF-VCO auto adjustment status in EEPROM are updated.
7. VIF-DEF
(
1chip
)
intelli
g
ent monitor output, IM input mode are recovered.
S-TRAP
1. If there is S-TRAP auto adjustment key input at item S-TRAP, a uto adjustment will be implemented.
2. S-TRAP OUTPUT is set by intelligent monitor output.
3. IM input becomes AD input.
4. S-Trap (1chip) is set to the value of V45(S-TRAP ADJ Start).
5. S_Trap_Result is set to the value of V45(S-TRAP ADJ Start).
6. S-Trap (1chip) is increased until the minimum input voltage becomes m inimum.
7. Wait 20ms before sampling the new_ AD_data.
8. When adjustment is completed, OSD display and S-TRAP auto adjustment status in EEPROM are updated.
9. S-TRAP
(