Service manual

7
25C340
Below are the adjustments ranges and initial values for FIX VALUE category.
FIX VALUE
F01 OPTION 1 00-FF B3 B3
F02 OPTION 2 00-FF 07 07
F03 E-SAVE 00-3F 2A 2A
F04 TUNER SETUP 00, 01 00 00
F05 R-TONE RD 00-7F 03 03
F06 R-TONE BD 00-7F 7C 7C
F07 B-TONE RD 00-7F 00 00
F08 B-TONE BD 00-7F 04 04
F09 FM LEVEL 00-1F 16 16
F10 AFC GAIN 00, 01 00 00
F11 G DRIVE 00, 0F 0F 0F
F12 FBT BLK SW 00, 01 01 01
F13 V COMP 00-07 07 07
F14 OSD CONT 00-03 01 01
F15 SHARPNESS 00-3F 0D 0D
F16 FLT SYS 00-07 01 01
F17 KILLER OP 00-07 02 02
F18 PRE SHOOT 00-03 00 00
F19 CORING 00-03 04 04
F20 DC REST 00-03 02 02
F21 BS START 00-03 01 01
F22 BS GAIN 00-03 01 01
F23 ABL START 00-07 00 00
F24 R/B ANGLE 00-0F 08 08
F25 H BLK R 00-0F 03 03
F26 H BLK L 00-0F 00 00
F27 YC 00-07 05 04
SERVICE
POSITION
ADJUST ITEM
DATA
RANGE
INITIAL VALUE
(Hex)
Table - A
Below are the ranges and initial values for each adjustment and in each categories.
DEF
D01 H-PHASE 00-1F 0C
D02 V-SIZE 00-7F 40
D03 V-POSITION 00-3F 20
D04 CC-POSITION 00-FF 1A
D05 V-LINEARITY 00-1F 18 Must be "13"
D06 V-S-CORRECTION 00-1F 0C Must be "10"
SERVICE
POSITION
ADJUST ITEM
DATA
RANGE
INITIAL VALUE
ADJUSTMENT CONTENTS
Table - B