Service manual

7
26MR30
Below are the adjustments ranges and initial values for FIX VALUE category.
FIX VALUE
F01 OPTION 1 00-FF B0 A0
F02 OPTION 2 00-FF 04 0C
F03 E-SAVE 00-3F 23 2A
F04 TUNER SETUP 00, 01 00 00
F05 R-TONE RD 00-7F 19 03
F06 R-TONE BD 00-7F 00 7C
F07 B-TONE RD 00-7F 00 00
F08 B-TONE BD 00-7F 12 04
F09 FM LEVEL 00-1F 0C 0C
F10 AFC GAIN 00, 01 00 00
F11 G DRIVE 00, 0F 00 0F
F12 FBT BLK SW 00, 01 01 01
F13 V COMP 00-07 07 07
F14 OSD CONT 00-03 02 01
F15 SHARPNESS 00-3F 19 *1
F16 FLT SYS 00-07 00 01
F17 KILLER OP 00-07 04 02
F18 Y PRI 00-03 00 00
F19 CORING 00-07 04 04
F20 DC REST 00-03 02 02
F21 BS START 00-03 01 01
F22 BS GAIN 00-03 01 01
F23 ABL START 00-07 00 00
F24 R/B ANGLE 00-0F 08 08
F25 H BLK R 00-0F 04 03
F26 H BLK L 00-0F 04 00
SERVICE
POSITION
ADJUST ITEM
DATA
RANGE
INITIAL VALUE
(Hex)
Table - A
Below are the ranges and initial values for each adjustment and in each categories.
DEF
D01
H-PHASE 00-1F 0C
D02 V-SIZE 00-7F 40
D03
V-POSITION 00-3F 20
D04 CC-POSITION 00-FF 1A
D05 V-LINEARITY 00-1F 10 Must be "13"
D06 V-S-CORRECTION 00-1F 10 Must be "10"
SERVICE
POSITION
ADJUST ITEM
DATA
RANGE
INITIAL
VALUE
ADJUSTMENT CONTENTS
Table - B
TUNER TYPE (Hex)
VTUVTST5UF770 0D
VTUENV56D82-1 12
VTUENV56DA1G3 12
VTUVTST5UF670 0D
VTUVTST5UF740 0D
*1: type of tuner