OPERATION MODE SELECTION
Operation according to selected time program
Operation according to the selected time program with day and night tempera-
ture which is set on the controller.
Operation according to the selected time program with day and night tempera-
ture which is set on the room unit DD2+.
Operation mode according to day temperature
Controller operates according to the requested day temperature which is set on
controller.
Operation mode according to night temperature
Controller operates according to the requested night temperature which is set
on controller.
Switch-off
Controller is switched off. Frost protection remains active, if operation mode
heating is selected. Overheating protection remains active, if operation mode
cooling is selected.
OPERATION MODE FOR W. H. W. WARMING:
D. h. w. warming according to selected time program
D. h. w. is warmed according to the selected time program.
Permanent activation of d. h. w. warming
D. h. w. warming operates continuously.
Switch-off
D. h. w. is not being warmed.
* The menu is only available in schemes with two heating circuits.
In the menu are selection of operation mode for each heating circuit, for d. h. w. warming
and other operation modes. Following operation modes are available in the menu.
First heating circuit
Second heating circuit *
Domestic hot water
Manual operation
Switchover between heating and cooling
Emissions analysis
OPERATION MODE FOR THE FIRST AND THE SECOND HEATING CIRCUIT: