Para-
meter
Parameter name Parameter description Setting
range
Default
setting
S1.12 OUTPUT R9 FUNCTION
Setting of output R9 operation mode.
1 - KTF, output is used for solar differential thermostat.
2 - KF2, output is used for solid fuel boiler differential
thermostat.
3 - output is used for d. h.w. circulation
4 - output is used for d. h. w. warming with electric heater
5 - output is used to control boiler return temperature (bypass
pump), set also S1.4=9 (for sensor T1) or S1.5=12 (for sensor
T8).
6 - output is used to control boiler primary pump
7 - output is used to control heat pump
1- KTF
2- KF2
3- D. H. W.
CIRC.
4- EL. HEA-
TER
5- BYPASS
PUMP
6- PRIMARY
PUMP
7- HEAT
PUMP
1
S1.13 SENSOR T1 CALIBRA-
TION
Correction of displayed measured temperature for sensor T1. -5 ÷ 5 K
0
S1.14 SENSOR T2 CALIBRA-
TION
Correction of displayed measured temperature for sensor T2. -5 ÷ 5 K
0
S1.15 SENSOR T3 CALIBRA-
TION
Correction of displayed measured temperature for sensor T3. -5 ÷ 5 K
0
S1.16 SENSOR T4 CALIBRA-
TION
Correction of displayed measured temperature for sensor T4. -5 ÷ 5 K
0
S1.17 SENSOR T5 CALIBRA-
TION
Correction of displayed measured temperature for sensor T5. -5 ÷ 5 K
0
S1.18 SENSOR T6 CALIBRA-
TION
Correction of displayed measured temperature for sensor T6. -5 ÷ 5 K
0
S1.19
SENSOR T7 CALIBRA-
TION
Correction of displayed measured temperature for sensor T7. -5 ÷ 5 K
0
S1.20
SENSOR T8 CALIBRA-
TION
Correction of displayed measured temperature for sensor T8. -5 ÷ 5 K
0

Para-
meter
Parameter name Parameter description Setting
range
Default
setting
S2.1 INFLUENCE OF ROOM
TEMP. DEVIATION


0,0 ÷ 3,0
1
S2.2 INFLUENCE OF ROOM
SENSOR T1 OR T8




connected

connected


This setting has affect only if S1.4=1 (for sensor T1) or S1.5=4
(for sensor T8).
1- AUTO
2- YES
3- NO
1