PARAMETERS FOR FLOOR DRYING


Para-
meter
Parameter name Setting range Default
setting
F1.1 FLOOR DRYING
0- NO
1- CIRCUIT 1
2- CIRCUIT 2
3- CIRCUIT 1 & 2
0
F1.2 INTERVAL 1: DURATION
1 ÷ 15 days
10
F1.3 INTERVAL 1: START TEMPERATURE
10 ÷ 60 °C
20
F1.4 INTERVAL 1: END TEMPERATURE
10 ÷ 60 °C
20
F1.5 INTERVAL 2: DURATION
1 ÷ 15 days
5
F1.6 INTERVAL 2: START TEMPERATURE
10 ÷ 60 °C
20
F1.7 INTERVAL 2: END TEMPERATURE
10 ÷ 60 °C
50
F1.8 INTERVAL 3: DURATION
1 ÷ 15 days
10
F1.9 INTERVAL 3: START TEMPERATURE
10 ÷ 60 °C
50
F1.10 INTERVAL 3: END TEMPERATURE
10 ÷ 60 °C
50
F1.11 INTERVAL 4: DURATION
1 ÷ 15 days
5
F1.12 INTERVAL 4: START TEMPERATURE
10 ÷ 60 °C
50
F1.13
INTERVAL 4: END TEMPERATURE
10 ÷ 60 °C
20
The procedure for F parameters setting is the same as the procedure for
service settings (see 41).
Para-
meter
Parameter name Parameter description Setting range Default
setting
S6.18
HEAT PUMP - OUTDOOR
TEMP. FOR BIVALENT
OPERATION MODE
Setting of outdoor temperature for bivalent operation
mode of heat pump and other heat source. Below setted
temperature the controller makes switchover between
heat sources immediately when heat pump cannot supply
requested temperature. Above setted temperature the
controller makes switchover between heat sources on

of switchover between heat sources provides maximum

solely cannot cover complete heating demand.
-30 ÷ 20 °C
-3
S6.19
HEAT PUMP - MIN.
OUTDOOR TEMP. FOR
MONOVALENT OPERATI-
ON MODE
Setting of minimum outdoor temperature for system with
heat pump and other heat source, above which solely
heat pump operation is allowed.
-30 ÷ 20 °C
7