Service manual

1-2
AY-ZP35PR
ITEMS
MODEL INDOOR UNIT
AY-ZP40PR
OUTDOOR UNIT
AE-Z40PR
Rated cooling capacity (Min. – Max.) kW 3.5 (1.3 - 4.0)
Rated heating capacity (Min. –Max.) kW 4.0 (0.9 - 6.0)
Moisture removal (at cooling) Liters/h 1.2
Electrical data
Phase Single
Rated frequency Hz 50
Rated voltage V 220-240
Rated current
(Min - Max.)
Cooling A 4.8 ( 1.8 - 6.5 )
Heating A 4.8 ( 1.3 - 8.5 )
Rated input
(Min - Max.)
Cooling W 1000 (340 - 1350)
Heating W 1020 (260 - 1800)
Power factor
Cooling % 91
Heating % 92
Maximum operating current A 9.3
Compressor Type Hermetically sealed rotary type
Model 5RS102XBE01
Oil Charge 320cc (RB68A)
Refrigerant system Evaporator Louver Fin and Grooved tube type
Condenser Corrugate Fin and Grooved tube type
Control Expansion valve
Refrigerant (R410A) 990g
De-lce system Micro computer controled reversed systems
Noise level
(at cooling)
High dB(A) 44 47
Low dB(A) 35 -
-
-
Soft dB(A) 30
45
40
35
48
-
Noise level
(at heating)
High dB(A)
Low dB(A)
Soft dB(A)
Fan system
Drive Direct drive
(at cooling)
High m
3
/min. 12.3 32.5
Low m
3
/min. 8.7 -
Soft m
3
/min. 6.9 -
(at heating)
High m
3
/min.
Low m
3
/min.
Soft m
3
/min.
Fan
Propeller fan
Connections
Refrigerant coupling Flare type
Refrigerant tube size (Gas, Liquid) inch 3/8", 1/4"
Drain piping mm 
Others
Safety device Fan motors : Thermal fuse
Fuse, Micro computer control
Polypropylene net (Washable)
Net dimensions Width mm 860 780
Height mm 292 540
Depth mm 205 265
Net/Gross weight kg 9 34
NOTE:The conditions of star “
” marked item are based on “EN14511”.
2. AY-ZP40PR – AE-Z40PR