Specifications

MX-3610N SIMULATION 5 – 52
Code descriptions
List of destination groups
X HL_US GLOSS PAPER Glossy paper TH_US set value 70 - 230 180 180 180 180 180 180
Y HL_UM E-STAR Preheating TH_UM set value 30 - 200 100 120 115 100 120 115
Z HL_US E-STAR Preheating TH_US set value 30 - 200 145 155 150 145 155 150
AA HL_UM PRE-JOB Preheat mode restore complete temperature 30 - 200 135 135 145 140 145 155
AB HL_LM E-STAR Preheating TH_LM set value 30 - 200 70 90 90 70 90 90
AC HL_UM HEAVY2 PAPER Heavy paper 2 TH_UM set value 70 - 230 170 170 170 170 170 170
AD HL_LM HEAVY2 PAPER Heavy paper 2 TH_LM set value 30 - 200 120 120 120 120 120 120
AE HL_US HEAVY2 PAPER Heavy paper 2 TH_SU set value 70 - 230 170 170 170 170 170 170
AF HL_UM WARMUP_120L TH_UM set value when Warm-Up at 120C or below 70 - 230 140 150 160 145 160 165
AG HL_LM WARMUP_120L TH_LM set value when Warm-Up at 120C or below 30 - 200 90 105 105 110 115 115
AH HL_US WARMUP_120L TH_US set value when Warm-Up at 120C or below 70 - 230 130 140 160 135 160 165
AI LO_WARMUP_TIME AF - AH applying time
(Timer from completion of Ready)
0 - 255 10 10 10 10 10 10
AJ HL_UM WARMUP_120H TH_UM set value when Warm-Up at 120C or above 70 - 230 140 150 160 145 160 165
AK HL_LM WARMUP_120H TH_LM set value when Warm-Up at 120C or above 30 - 200 90 105 105 110 115 115
AL HL_US WARMUP_120H TH_US set value when Warm-Up at 120C or above 70 - 230 130 140 160 135 160 165
AM HI_WARMUP_TIME AJ - AL applying time
(Timer from completion of Ready)
0 - 255 10 10 10 10 10 10
AN HI_WU_FM_ON_TMP FM prior rotation start TH_US when Warm-Up at alpha
C or above
30 - 200 30 30 30 30 30 30
AO HI_WU_END_TIME Warm-Up completion time when Warm-Up at alpha C
or above
0 - 255 16 16 16 16 16 16
AP HI_WU_JOB_SET_TMP Job enable TH_UM temperature when Warm-Up at
alpha C or above
70 - 230 140 150 160 145 160 165
AQ HI_WARMUP_BORDER Threshold value alpha to which SIM43-1-AN - AP is
applied
1 - 119707070707070
AR LO_WU_JOB_SET_TMP Job enable TH_UM temperature when Warm-Up at
alpha C or below
70 - 230 140 150 160 145 160 165
AS JOBEND_FUMON_TIME Fusing motor after rotation time after completion of a
job (Excluding heavy paper, OPH, and envelopes)
0 - 255 5 5 5 5 5 5
AT HL_UM_JOB_SET_TMP_
BW
Job enable temperature (B/W) when the upper roller
temperature is lower than alpha C
70 - 230 140 150 160 145 160 165
Item/Display Content
Setting
range
Default value (SW-A) Default value (SW-B)
Group
A
Group
B
Group
C
Group
A
Group
B
Group
C
TH_UM Fusing thermistor main (Front surface of paper) HL_UM Heater lamp main (Heat roller for front surface of paper)
TH_LM Fusing thermistor main (Back surface of paper) HL_LM Heater lamp main (Heat roller for front surface of paper)
TH_US Fusing thermistor sub (Front surface of paper) HL_US Heater lamp sub (Heat roller for front surface of paper)
SW-A Setting value when plain paper is selected in the system setting/device setting/fusing control setting.
SW-B Set value when heavy paper is selected in the system setting/device setting/fusing control setting.
The set value displayed in this simulation differs depending on plain paper or heavy paper which is selected in the system setting/device setting/fusing
control setting.
(Example) When plain paper is selected in the system setting/device setting/fusing control setting, the value of SW-A is displayed.
Group Destination
Group AJAPAN––––
Group B U. S. A CANADA INCH
Group C EUROPE U. K AUS. AB_B CHINA