Specifications

MX-3610N SIMULATION 5 – 69
43-24
Purpose
Adjustment/Setup
Function (Purpose)
Used to set the correction of the tempera-
ture adjustment value of SIM 43-1 and 43-
4.
Section
Operation/Procedure
1) Select an item to be set with scroll keys.
2) Enter the set value with 10-key.
3) Press [OK] key.
The set value in step 2 is saved.
Correction value: -49 - +49, Input value: Actually inputted value (1 -
99)
18cpm/20cpm machine
* Each temperature correction value: 1 count for 1C change in temperature control
* Each paper exit count: 1 count = 1 sheet change
* Each cool down time: 1 count = 1sec change
Code descriptions
Correction value -49 -25 -5 0 5 25 49
Input value 1 25 45 50 55 75 99
Item/Display Content
Default value (SW-A) Default value (SW-B)
Group
A
Group
B
Group
C
Group
A
Group
B
Group
C
A NN_120_FUS_DUP_HL_UM Correction value for SIM43-4-A, E at 120C or below in N/N
Warm-Up
50 50 50 50 50 50
B NN_120_FUS_DUP_HL_LM Correction value for SIM43-4-B, F at 120C or below in N/N
Warm-Up
50 50 50 50 50 50
C LL_120_FUS_DUP_HL_UM Correction value for SIM43-22-A, E at 120C or below in N/N
Warm-Up
50 50 50 50 50 50
D LL_120_FUS_DUP_HL_LM Correction value for SIM43-22-B, F at 120C or below in N/N
Warm-Up
50 50 50 50 50 50
E HH_120_FUS_DUP_HL_UM Correction value for SIM43-23-A, E at 120C or below in N/N
Warm-Up
50 50 50 50 50 50
F HH_120_FUS_DUP_HL_LM Correction value for SIM43-23-B, F at 120C or below in N/N
Warm-Up
50 50 50 50 50 50
G NN_120_FUS_DUP_CNT Fusing duplex paper exit count under NN environment 5 5 5 5 5 5
H LL_120_FUS_DUP_CNT Fusing duplex paper exit count under LL environment 10 10 10 10 10 10
I HH_120_FUS_DUP_CNT Fusing duplex paper exit count under HH environment 5 5 5 5 5 5
J COOL_DOWN_HEAVY Cool down time heavy paper 5 5 5 5 5 5
K COOL_DOWN_OHP Cool down time OHP 10 10 10 10 10 10
L COOL_DOWN_ENVELOPE Cool down time envelope 15 15 15 15 15 15
M NN_120_FUS_DUP_HL_US Correction value for SIM43-4-C, G at 120C or below in N/N
Warm-Up
50 50 50 50 50 50
N LL_120_FUS_DUP_HL_US Correction value for SIM43-22-C, G at 120C or below in L/L
Warm-Up
50 50 50 50 50 50
O HH_120_FUS_DUP_HL_US Correction value for SIM43-23-C, G at 120C or below in H/H
Warm-Up
50 50 50 50 50 50
P HL_UM THIN PAPER BW Thin paper BW-TH_UM 130 130 130 130 130 130
Q HL_LM THIN PAPER BW Thin paper BW-TH_LM 120 120 120 120 120 120
R HL_US THIN PAPER BW Thin paper BW-TH_US 130 130 130 130 130 130
S HL_UM THIN PAPER CL Thin paper COL-TH_UM 140 140 140 140 140 140
T HL_LM THIN PAPER CL Thin paper COL-TH_LM 130 130 130 130 130 130
U HL_US THIN PAPER CL Thin paper COL-TH_US 140 140 140 140 140 140
V HL_UM THIN PAPER READY Thin paper Ready-TH_UM 145 145 145 145 145 145
W HL_UM REC PAPER BW Recycled paper BW-TH_UM 135 160 160 135 160 160
X HL_LM REC PAPER BW Recycled paper BW-TH_LM 125 140 140 125 140 140
Y HL_US REC PAPER BW Recycled paper BW-TH_US 135 155 155 135 155 155
Z HL_UM REC PAPER CL Recycled paper COL-TH_UM 145 170 170 145 170 170
AA HL_LM REC PAPER CL Recycled paper COL-TH_LM 135 140 140 135 140 140
AB HL_US REC PAPER CL Recycled paper COL-TH_US 145 160 160 145 160 160
AC HL_UM REC PAPER READY Recycled paper Ready-TH_UM 155 180 180 155 180 180
TH_UM Fusing thermistor main (Front surface of paper) HL_UM Heater lamp main (Heat roller for front surface of paper)
TH_LM Fusing thermistor main (Back surface of paper) HL_LM Heater lamp main (Heat roller for back surface of paper)
TH_US Fusing thermistor sub (Front surface of paper) HL_US Heater lamp sub (Heat roller for front surface of paper)
SW-A Setting value when plain paper is selected in the system setting/device setting/fusing control setting.
SW-B Set value when heavy paper is selected in the system setting/device setting/fusing control setting.
The set value displayed in this simulation differs depending on plain paper or heavy paper which is selected in the system setting/device setting/fusing
control setting.
(Example) When plain paper is selected in the system setting/device setting/fusing control setting, the value of SW-A is displayed.