Specifications

MX-3610N SIMULATION 5 – 77
44-12
Purpose
Operation data display
Function (Purpose)
Used to display the operation data of the
high density process control and the image
density sensor (registration sensor).
Section
Image process (Photoconductor/Develop-
ing)
Operation/Procedure
Select a display mode with [TARGET] [PATCH] keys.
44-13
Purpose
Adjustment/Setup
Function (Purpose)
Used to perform the color image sensor
(image registration sensor F) calibration.
Section
Operation/Procedure
1) Remove the BK developing unit, the BK OPC drum unit, and
the primary transfer unit. Attach the calibration jig.
2) Press [EXECUTE] key.
Calibration is performed, and the data are displayed.
3) Install the BK developing unit, the BK OPC drum unit, and the
primary transfer unit.
4) Press [EXECUTE] key.
44-14
Purpose
Operation data display
Function (Purpose)
Used to display the output level of the tem-
perature and humidity sensor.
Section
Process (OPC drum, development)/Fusing/
LSU
Operation/Procedure
The output levels of the fusing temperature sensor, the machine
temperature sensor, and the humidity sensor are displayed.
OTHER CRUM DESTINATION CRUM destination (Main unit data) - -
MODEL TYPE Machine model type 0 - 1 0
CRUM DEST_K CRUM destination (CRUM data) - -
CRUM DEST_C
CRUM DEST_M
CRUM DEST_Y
CNT PROCON COUNT HV High density process control number of executions 0 - 99999999 0
PROCON COUNT HT Halftone process control number of executions 0 - 99999999 0
Mode Item/Display (*: Correction value) Content Display range
Default
value
Mode Item/Display Content
Display
range
Default
value
TARGET CARB DATA Standard reflection plate
detection level
0 - 255 108
SEAL ADJ
DATA
Jig patch seal detection
level when executing
SIM 44-13
1 - 255 108
ADK_SL (K) Development
characteristics gradient
coefficient (High density
process control
operation)
-9.99 -
9.99
0
ADK_INT(K) Development
characteristics intercept
level (High density
process control
operation 0V)
-999.9 -
999.9
0
TARGET (K) High density process
control target density
level (K)
0.00 -
255.00
0
TARGET
(C/M/Y)
High density process
control target density
level (C/M/Y)
0.00 -
255.00
0
PATCH n-1 High density process
control nth time toner
patch density level 1
(n=1-5)
0 - 255 0
n-2 Toner patch data nth
time patch 2 (n=1-5)
0 - 255 0
n-3 Toner patch data nth
time patch 3 (n=1-5)
0 - 255 0
n-4 Toner patch data nth
time patch 4 (n=1-5)
•BK only
0 - 255 0
n-5 Toner patch data nth
time patch 5 (n=1-5)
•BK only
0 - 255 0
PATCH n-1 Toner patch data nth
time patch 1 (n=6-10)
0 - 255 0
n-2 Toner patch data nth
time patch 2 (n=6-10)
0 - 255 0
n-3 Toner patch data nth
time patch 3 (n=6-10)
0 - 255 0
n-4 Toner patch data nth
time patch 4 (n=6-10)
•BK only
0 - 255 0
n-5 Toner patch data nth
time patch 5 (n=6-10)
•BK only
0 - 255 0
Item/Display Content
Setting
range
Default
value
A PCS_CL CARB OUT Calibration plate sensor
value
1 - 255 108
B PCS_CL LED ADJ Color sensor light
emitting quantity
adjustment value
1 - 255 21
Error display Content
SEN ADJ ERR Color image sensor sensitivity adjustment
abnormality
SHUTTER CLOSE ERR Primary transfer operation abnormality
ERROR Compulsory stop
Item/Display Content Display range
TH_UM Fusing main thermistor
differential input level (C) /
(AD value)
Temperature:
0 - 255C (1C)
AD value: 0-1023
TH_UM_AD1 Fusing thermistor detection
level for compensation (C)
/ (AD value)
Temperature:
0.0-255.0C (0.2C)
AD value: 0-1023
TH_UM_AD2 Fusing thermistor detection
level (AD value)
AD value: 0-1023
TH_LM Fusing thermistor A/D value
(temperature C) (Fusing
roller B edge)
Temperature:
0 - 255C (1C)
AD value: 0-1023
TH_US Fusing sub thermistor A/D
value (temperature C)
(Fusing belt)
Temperature:
0 - 255C (1C)
AD value: 0-1023
TEMPRATURE Process control thermistor
detection level
Temperature:
-40.0 - 60.0C (0.1C)
AD value: 0-1023