Purpose
Setting
Function (Purpose)
Used to set the OPC drum idle rotation.
Section
Process
Operation/Procedure
1) Select an item to be set with the scroll key.
2) Enter the set value with 10-key.
3) Press [OK] key.
The initial value must be set unless any special change is required.
The execution YES/NO of the OPC drum idle rotation is determined
by the AND condition of TIME, AREA1, and AREA 2.
To execute the OPC drum idle rotation, set item B (AREA 1) to "0,"
and item C (AREA2) to "15."
However, idle rotation is performed in a certain interval while in shut
off. This must be fully explained to the user.
44-21
Purpose
Adjustment/Setup
Function (Purpose)
Used to set the halftone process control tar-
get.
Section
Process
Operation/Procedure
Press [EXECUTE] key.
The halftone process control target is set and the operation data
are displayed.
44-22
Purpose
Operation data display
Function (Purpose)
Used to display the toner patch density
level in the halftone process control opera-
tion.
Section
Process
Operation/Procedure
1) Select the display mode with [1ST STEP],[2ND STEP] key.
The toner patch density level made in the halftone process
control operation is displayed.
44-24
Purpose
Operation data display
Function (Purpose)
Used to display the correction target and
the correction level in the halftone process
control operation.
Section
Process
Operation/Procedure
1) Select the display category with [NEXT] key.
2) Select a target adjustment color with [K] [C] [M] [Y] key.
HUMIDITY Process control humidity
sensor detection level
Humidity:
5.0-90.0% (0.1%),
AD value: 0-1023
TH1_LSU LSU thermistor detection
level (A/D value) (C)
Temperature:
5.0-60.0C (0.1C)
AD value: 0-255
Item/
Display
Content
Setting
range
Default
value
A TIME Idle rotation interval (time interval
between the previous OPC drum idle
rotation and the next one) setting (h)
0 - 255 6
B AREA1 Environmental area difference
judgment threshold value setting
(difference between the previous
OPC drum idle rotation and the
current one)
0 - 5 2
C AREA2 Environmental area conditions (AND
condition of the previous OPC drum
idle rotation and the current one)
1 - 15 1
D CYCLE Previous rotation time setting (sec)
in the process control when
recovered from power ON,
preheating/sleep mode.
0 - 255 0
Display Content
COMPLETE Normal complete
ERROR COLOR SENSOR
ADJUSTMENT
Color image density sensor
sensitivity adjustment error
ERROR BLACK SENSOR
ADJUSTMENT
Black image density sensor
sensitivity adjustment error
[YMCK] High density process control error
[YMCK]
OTHER Other errors
Item/Display Content Display range
Item/Display Content
ID_n Patch data display
(PTK: n = 1 - 24, PTC/PTM/PTY: n = 1 - 16)
BASE1 Belt substrate data (START)
BASE5 Belt substrate data (LAST)
Category Item/Display Content
Coefficient [EX-LOW] Coefficient of the
approximation formula of the
minimum density
[LOW] Coefficient of the
approximation formula of the
low density
[CONNECT] Coefficient of the
approximation formula of when
connecting the low density and
the medium density
[MID] Coefficient of the
approximation formula of the
medium density
[HIGH] Coefficient of the
approximation formula of the
high density
[CONNECT POINT] Each density section
connection output ratio
Reference
value
[SENSOR_TARGET] Halftone process control
reference value
Correction
value
[S_VALUE] Halftone process control
correction value
For printer [PRINTER_S_VALUE] Printer halftone process control
correction value
[PRINTER_BASE_
DITHER_VALUE]
Printer halftone process control
reference dither value
[PRINTER_AUTO_
HT_VALUE]
Printer auto density adjustment
correction value
Previous
correction
value
[BEFORE S_VALUE] Previous halftone process
control value