Specifications

MX-3610N SIMULATION 5 – 81
Setting of the
execution
conditions of
the process
control
L LO-COV Setting of the execution judgment of the
process control in continuous printing of
low print ratio images
Enable 0 - 1 0 0
Inhibit 1
M TonerCA-END Setting of the process control interval
reduction when the toner cartridge
remaining quantity is 25% or less (If this is
set to Enable, item M RATIO is changed.)
Enable 0 - 1 0 1
Inhibit 1
N AVERAGE-PAGE Setting of the number of pages of item HI-
COV set value 2
1: 10 pages - 5: 50 pages
1 step corresponds to 10
pages.
1 - 5 1 3
5
O LIMIT PAGE Setting of the number of connected jobs of
the process control and of the limit number
of the process control
1: 10 pages - 10: 100
pages
1 step corresponds to 10
pages.
1 -10 1 10
A number of reservation jobs are
connected. When the number of jobs
exceeds the specified number of pages
(the set value of this setting), the process
control is performed. / The process control
is performed by AND conditions of item
REV condition and the specified number of
pages (the set value of this setting).
10
P PIX_RATIO_BK Magnification ratio setting (%) of the BK toner count specified value
The set value of 100 corresponds to K print of A4 at the print ratio of 5%.
1 - 999 10
Q PIX_RATIO_CL Magnification ratio setting (%) of the color (CMY) toner count specified
value
The set value of 100 corresponds to K print of A4 at the print ratio of 5%.
1 - 999 10
R INTERVAL TIME Setting of the leaving time when turning ON the power (including the
sleep recovery time) (h: hour)
1 - 255 3
S HUM HOUR Interval setting of the temperature and humidity monitoring time of
"HUM" (unit: 10 minutes)
1 - 24 2
T HUM_DIF The specified value of the area difference in humidity between the level
at execution of the previous control and the current humidity (Applied to
item HUM)
1 - 9 2
U BK_RATIO Magnification ratio setting (%) of the specified value of the BK OPC
drum traveling distance of "REV2_BK"
1 - 999 (Entry of 20
corresponds to
100,000mm.)
15
V M_RATIO Magnification ratio setting (%) of the M OPC drum traveling distance of
"REV2_CL"
1 - 999 (Entry of 20
corresponds to
100,000mm.)
15
W COLOR BORDER Judgment criteria whether the BK high
density process control is individually
performed or not (Setting of the ratio of the
M OPC drum rotation distance for the K
OPC drum rotation distance (%))
0: The BK process control
is executed regardless of
the M OPC drum traveling
distance.
0 - 999 20
1 - 999: 1 - 999(%)
X BK ONLY Setting of the frequency of execution of the
4-color high density process control when
only monochrome output is continued (The
result of this setting is applied only when
the M OPC drum rotation distance is
smaller than the set value of COLOR
BORDER.)
Frequency of once for 5
times
0 - 6 0 5
Frequency of once for 1 - 5
times
1 - 5
The 4-color high density
process control is always
performed.
6
Y HT_DIF HT process control execution judgment developing bias variation value 1 - 255 40
Setting of the
execution
condition of the
registration
adjustment
ZRG_ON_
SYNC
CL Setting of execution of the registration adjustment when executing the
process control when turning ON the power
When the color
process control is
executed.
00
ALL Executed
regardless of the
process control.
1
CL/BK When the color
process control
and the K process
control are
executed.
2
AA RG_TEMP_TIMER Time interval from registration adjustment after turning ON the power to
the next execution.
0 - 240
(MINUTE)
0
AB RG_PERM_TIMER Setting of inhibit time of execution of the registration adjustment 0 - 15
(HOUR)
1
AC RG_HOUR_TIMER Setting of the interval time of execution of the registration adjustment 0 - 15
(Above)+(HOUR)
5
AD
RG_BW_SYNC Setting of Enable/Disable of the
registration adjustment after a
monochrome job
Enable 0 - 1 0 1
Inhibit 1
Mode Item/Display Content Setting range
Default
value