Specifications

MX-3610N SIMULATION 5 – 118
*1: The color image skew adjustment is performed according to this display value.
When "R" is displayed in front of the value, turn and click the skew adjustment screw (LSU) clockwise by the value.
When "L" is displayed in front of the value, turn and click the skew adjustment screw (LSU) counterclockwise by the value.
*2: The color image skew adjustment is performed according to this display value.
When "R" is displayed at the head of the value, turn the skew adjustment screw (LSU) clockwise by the number of the value.
When "L" is displayed at the head of the value, turn the skew adjustment screw (LSU) counterclockwise by the number of the value.
At that time, the values under the decimal point are rounded.
Error displays in case of abnormal end
Item/Display Content Setting range (unit)
Color/
History
Default
value
NOTE
MAIN F - REG_M_F
(VALUE)
Registration adjustment
correction amount main scanning
direction F
1.0 - 199.0 (0.1) CMY/- 100
( ) REG_M_F (DIF) Registration value correction
amount from the previous one,
main scanning F
-199.0 - 199.0 (0.1) CMY/- 0
MAIN R - REG_M_R
(VALUE)
Registration adjustment
correction value, main scanning
direction R
1.0 - 199.0 (0.1) CMY/- 100
( ) REG_M_R
(DIF)
Registration value correction
amount from the previous one,
main scanning R
-199.0 - 199.0 (0.1) CMY/- 0
SUB - REG_SUB
(VALUE)
Registration adjustment
correction value, sub scanning
direction
1.0 - 199.0 (0.1) CMY/- 100
( ) REG_SUB (DIF) Registration value correction
amount from the previous one,
sub scanning
-199.0 - 199.0 (0.1) CMY/- 0
SKEW CMY SKEW_CLC SKEW adjustment rotating
direction and the number of clicks
(CMY)
L99.9 - R99.9 (0.1) KCMY/- 0 If the value is plus, L is
displayed to left side of
numerical value. If the value is
minus, R is displayed to left
side of numerical value.
When the value is -2.1 - +2.1,
"(OK)" is place at the back of
the value. For the other cases,
"(NG)" is displayed. *1
ALL_
ROTATE
SKEW adjustment rotating
direction and the number of clicks
(K)
If the value is plus, L is
displayed to left side of
numerical value. If the value is
minus, R is displayed to left
side of numerical value.
When the value is -1.6 - +1.6,
"(OK)" is place at the back of
the value. For the other cases,
"(NG)" is displayed. *2
PHASE PHASE_ADJ Phase adjustment value (1: Value
of this time, 2: Value of the
previous time)
Angle step 0 (1) 45 (2) 90
(3) 135 (4) 180 (5) 225
(6) 270 (7) 315 (8)
1 - 8 (1) -/2 1 -
Error code Error display Error content Description
Forcible end error - SUSPENDED Door open end Door open during operation
- SUSPENDED CA end CA button pressed during operation
- - OFF end Unconfirmed operation during operation (Power OFF)
Basic error 1 TONNER EMPTY Toner Empty BK or ALL Color toner EMPTY detection
2 BEFOR BEHAVIOR Other condition Other condition
4 SENSOR CALIBLATION F Calibration error F The target is not reached by 3 times of retry of F or R
5 SENSOR CALIBLATION R Calibration error R
6 SENSOR CALIBLATION FR Calibration error FR
7
TIME OVER Time error No data are obtained for 90sec from data acquisition
8 PROCESS CONTROL Process control error Process control error detection
Sub scanning
adjustment error
10 - 47 SUB XXX XXXX XXX
Main scanning
adjustment error
50 - 88 MAIN XXX XXXX XXX
Others 99 OTHER 99 Other errors Other errors