AL-1651CS TEST COMMAND, TROUBLE CODES 10 - 11
26 03 Second cassette setting
(2ND TRAY)
[Function]
When this test command is executed, the current set second cassette is displayed. Enter the code
number corresponding to the desired second cassette and press [ENTER/START] key to save the
setting.
[Operation]
The operation is similar to test command 21-01.
04 Main unit duplex setting
(DPLX)
[Function]
When this test command is executed, the current set duplex is displayed. Enter the code number cor-
responding to the desired duplex and press [ENTER/START] key to save the setting.
[Operation]
The operation is similar to test command 21-01.
06 Destination setting
(DESTINATION)
[Function]
When this test command is executed, the current set destination is displayed. Enter the code number
corresponding to the desired destination and press [ENTER/START] key to save the setting.
For Japan AB series, there is no schedule for production.
[Operation]
The operation is similar to test command 21-01.
07 Machine conditions check
(CPM)
[Function]
When this test command is executed, the current machine setting is displayed.
[Operation]
20 Rear edge void setting (END
EDGE)
[Function]
When this test command is executed, the current set rear edge void is displayed. Enter the code num-
ber corresponding to the desired rear edge void and press [ENTER/START] key to save the setting.
[Operation]
The operation is similar to test command 21-01.
Main
code
Sub
code
Contents Details of function/operation
Code number Second cassette Display item
0 Second cassette NO OFF
1 Second cassette YES ON
Code number Duplex Display item
0 Duplex NO OFF
1 Duplex YES ON
Code number Destination Display item
0 Inch series INCH
1 EX Japan AB series AB
2 Japan AB series
3 China (EX Japan AB series + China paper support) CHINA
CPM Coy quantity Remark
10 CPM 10
12 CPM 12
13 CPM 13
14 CPM 14
15 CPM 15
16 CPM 16
1) The machine setting is displayed.
26-07 CPM
10 CPM
Code number Setting Display item Remark
0 Rear edge void NO OFF
1 Rear edge void YES ON Default