Service manual

AL-2041 SIMULATION, TROUBLE CODES 10 - 11
43 04 Fusing temperature setting
in multi copy
[Function]
For 20th sheet or later in multi copy, the fusing temperature is automatically changed from the
temperature set with simulation 43-01 to the temperature set with this simulation.
When this simulation is executed, the current set code number is displayed. Enter the code
number and press [START] key to change the setting.
[Operation]
The operation is similar to simulation 43-01.
05 Fusing temperature setup in
duplex copy (AL-2041 only)
[Function]
In the case of duplex copy, the shift temperature set with this simulation is applied to the fusing
temperature.
When this simulation is executed, the current set code number is displayed.
Enter the desired code number and press [START] key to save the setting.
[Operation]
The operation is similar to simulation 26-02.
09 Postcard size paper fusing
control setting
[Function]
When this simulation is executed, the currently set code number is displayed.
Enter the code number and press [START] key, and the setting is changed.
Main
code
Sub
code
Contents Details of function/operation
* The cassette feed and the manual feed are controlled similarly.
Code Set temperature (°C) Remark
0 165
1 170
2 175
3 180
4 185
5 190
6 195
7 200
Mode Display lamp
Default
North
America
Europe
Main cassette paper feed AE mode lamp 3 3
Manual paper feed TEXT mode lamp 3 3
Main cassette paper feed (small-size) PHOTO mode lamp 1 3
Manual paper feed (small-size) AE mode lamp
TEXT mode lamp
13
Code Shift temperature (°C) Remark
0 ±0 Default
1–8
2–6
3–4
4–2
0
6+2
7+4
8+6
9+8
Code Shift temperature (°C) Remark
0 Cancel Default
1Set