Service manual

AL-2030/2040CS/2050CS SIMULATION, TROUBLE CODES 10 - 16
43 01 Fusing temperature setting
(Normal copy)
[Function]
Used to set the fusing temperature of 3rd or later sheet. (For 1st and 2nd sheets, SIM 43-14 is
used.)
When this simulation is executed, the current set code number is displayed. Press [ ] [ ] key
(or [Numeric] key for the AL-2050CS) to change the setting and press [ENTER]/[START] key to
save the setting into the EERPOM. The machine goes into the sub code entry standby mode.
The [Exposure mode selector] key (or [ ] [ ] key for the AL-2050CS) is used to select the
mode.
[Operation]
04 Fusing temperature setting
in multi copy
[Function]
For 20th sheet or later in multi copy, the fusing temperature is automatically changed from the
temperature set with simulation 43-1 to the temperature set with this simulation.
When this simulation is executed, the current set code number is displayed. Enter the code
number and press [ENTER]/[START] key to change the setting.
The cassette feed and the manual feed are controlled similarly.
[Operation]
The operation is similar to simulation 43-01.
Main
code
Sub
code
Contents Details of function/operation
* The cassette feed and the manual feed are controlled similarly.
Code Set temperature (°C) Remark Code Set temperature (°C) Remark
0 170 5 195 Default
1 175 6 200
2 180 7 205
3 185 8 210
4 190
Mode
Display item
(AL-2050CS)
Display item
(AL-2030/2040CS)
Main cassette paper feed & 2nd cassette paper feed TRAY1 AE mode lamp
Manual paper feed MFT TEXT mode lamp
AL-2050CS
1) Initial display <Main cassette paper feed
& 2nd cassette paper feed setting>
2) [ ] [ ] key: Mode selection
3) [Numeric] key: Value entry
4) [ENTER]/[START] key
Settles the entered value. The display is
shifted to the sub code input standby
menu.
AL-2030/2040CS
1) Press [Exposure mode selector] key to
change the mode.
2) Press [ ] [ ] key to set the value.
3) Press [START] key to fix the code
number.
43-01 FU TEMP
TRAY1 6( 0-8 )
43-01 FU TEMP
MFT 6( 0-8 )
43-01 FU TEMP
MFT 6( 0-8 )
Code Set temperature (°C) Remark
0 165
1 170
2 175
3 180
4 185
5 190
6 195
7 200
Mode
Display item
(AL-2050CS)
Display lamp
(AL-2030/2040CS)
Default
Main cassette paper feed & 2nd cassette
paper feed
TRAY1 AE mode lamp 3
Manual paper feed MFT TEXT mode lamp 3
Main cassette paper feed & 2nd cassette
paper feed (small-size)
TRAY1 SH PHOTO mode lamp 1
Manual paper feed (small-size) MFT SH AE mode lamp
TEXT mode lamp
1