Service manual

AL-2051 SIMULATION, TROUBLE CODES 10 - 16
43 01 Fusing temperature setting
(Normal copy)
[Function]
Used to set the fusing temperature of 3rd or later sheet. (For 1st and 2nd sheets, SIM 43-14 is
used.)
When this simulation is executed, the current set code number is displayed. Press [Numeric]
key to change the setting and press [ENTER]/[START] key to save the setting into the EER-
POM. The machine goes into the sub code entry standby mode.
The [ ] [ ] key is used to select the mode.
[Operation]
04 Fusing temperature setting
in multi copy
[Function]
For 20th sheet or later in multi copy, the fusing temperature is automatically changed from the
temperature set with simulation 43-01 to the temperature set with this simulation.
When this simulation is executed, the current set code number is displayed. Enter the code
number and press [ENTER]/[START] key to change the setting.
The cassette feed and the manual feed are controlled similarly.
[Operation]
The operation is similar to simulation 43-01.
Main
code
Sub
code
Contents Details of function/operation
* The cassette feed and the manual feed are controlled similarly.
Code Set temperature (°C) Remark Code Set temperature (°C) Remark
0 170 5 195 Default
1 175 6 200
2 180 7 205
3 185 8 210
4 190
Mode Display item
Main cassette paper feed TRAY1
Manual paper feed MFT
1) Initial display <Main cassette paper feed
setting>
2)[] [] key: Mode selection
3) [Numeric] key: Value entry
4) [ENTER]/[START] key
Settles the entered value. The display is
shifted to the sub code input standby
menu.
43-01 FU TEMP
TRAY1 6( 0-8 )
43-01 FU TEMP
MFT 6( 0-8 )
43-01 FU TEMP
MFT 6( 0-8 )
Code Set temperature (°C) Remark
0 165
1 170
2 175
3 180
4 185
5 190
6 195
7 200
Mode Display item Default
Main cassette paper feed TRAY1 3
Manual paper feed MFT 3
Main cassette paper feed (small-size) TRAY1 SH 1
Manual paper feed (small-size) MFT SH 1