Specifications

21
Setup
The followings are descriptions of the ADVANCED SETUP MENU.
Setting Automatic Logout Time (ADVANCED[1]Auto Logout Time)
If there is no input after a fixed time, AN-LS1 automatically disconnects network connection using the
Auto Logout function. It is possible to set the time until AN-LS1 is automatically disconnected in units
of a minute (from 1 to 65535 minutes).
advanced>1
Valid range : 0 to 65535 (minute)
note: if you enter 0, auto logout function will be disable.
Auto Logout Time : 5
Please Enter : 15
(change) >15
If the set value is made 0, the Auto Logout function is disabled.
COM Redirect Port Setting (ADVANCED[2]COM Redirect Port)
Setting of TCP port number capable of connecting using Sharp COM Redirection Software.
Can be set in the range of 1025 to 65535.
advanced>2
Valid range :1025 to 65535
COM Redirect Port :10002
Please Enter :10005
(change) > 10005
Enter 1 and press the return key.
Enter numerical value and press
the return key.
Display set numerical value.
Enter 2 and press the return key.
Enter numerical value and press
the return key.
Display set numerical value.