Service manual

AR-C200P Rev.5 67 /
1
H
G
0
B
A
3
A
F
E
6
7
2
4
5
9
8
1
C
D
2.3.41 Cassette/ Right Guide Assy
(1) Remove the printer unit chassis (see section 2.3.25).
(2) Remove the main feed Assy (see section 2.3.39).
(3) Remove the five screws 1 to detach the right cassette guide Assy 2. At the same time, the
earth plate 3 becomes detached.
(4) Remove the cassette lift spring 4, then detach the plastic slide 5, the cassette lift arm (L) 6
and the plastic roller 7.
(5) Unscrew the screw 8 to remove the paper size actuator 9.
(6) Unscrew the screw 0 to remove the paper size sensing PWB A in the downward direction.
(7) Remove the two feet B.
(8) Remove the cassette lock spring C, then remove the cassette lock D.
(9) Unscrew the two screws E to remove the 2nd tray connector F.
(10) Unscrew the screw G, then remove the duplex Assy ground contact H.
Figure 2-3-41 Printer Tray/ Right Guide Assy