Specifications

AR-FX12 SIMULATIONS, FAX SOFTWARE SWITCH 6-48
72 3,4 Upper limit of busy tone
detection time
(ON time)
Used to set the upper limit of detection time (ON time) of busy tone signal
frequency. To count a busy tone signal as 1 pulse, it must be detected for less
than the set time.
0 750ms
0
5,6 Lower limit of busy tone
OFF detection time
Used to set the lower limit time of OFF period when detecting the frequency of
busy tone signal.
Only when OFF signal of busy tone signal is detected for more than this lower
limit time, it is counted as one pulse.
0 250ms
0
7,8 Upper limit of busy tone
OFF detection time
Used to set the upper limit of OFF time when detecting the busy tone signal
frequency. If the busy tone signal is detected over this setup, it is not counted as
one pulse.
0 750ms
0
73 1-8 Not used 0
1
0
1
0
1
1
0
74 1-8 Not used 0
0
0
0
1
1
0
1
75 1-4 Lower limit of call signal
ON time
Used to set the lower limit of ON time for detection of pulses (number of times)
of call signal (CI). When CI signal ON is detected for more than the set time, it is
counted as 1 pulse.
The lower limit of ON time can be set in the range of
150 - 300ms by binary input of N (0 - 15) into "N x 10 + 150ms."
This switch substitutes for the sine wave of CI detection.
0 150ms
0
0
0
5-8 Upper limit of call signal
ON time
Used to set the upper limit of ON time for detection of pulses (number of times)
of call signal (CI). When CI signal ON is detected for less than the set time, it is
counted as 1 pulse.
The upper limit of ON time can be set in the range of
3000 - 4500ms by binary input of N (0 - 15) into "N x 100 + 3000ms."
0 3000ms
0
0
0
76 1-4 Lower limit of call signal
OFF time
Used to set the lower limit of call signal (CI) OFF time for detection of pulses
(number of times). When a CI signal OFF is detected for mote than the set OFF
time, it is judged as 1 pulse. The lower limit of OFF time can be set in the range
of 0 - 150ms by binary input of N (0 - 15) into "N x 100ms."
0 700ms
1
1
1
SW
No.
Bit
No.
Item Switch selection and function USA Initial value Key
operator
Bit No. 3 4
750ms 0 0
650ms 0 1
1000ms 1 0
2850ms 1 1
Bit No. 5 6
250ms 0 0
150ms 0 1
450ms 1 0
350ms 1 1
Bit No. 7 8
750ms 0 0
650ms 0 1
1000ms 1 0
2850ms 1 1
[06]SIMULATIONS FAXSOFTWARESWITCH.fm 48 ページ 2004年10月26日 火曜日 午後3時44分