Specifications

2. Communication section
Note: These items are factory adjusted when shipping according to
FCC standards. Therefore, do not change the setting in the
market.
A. Dial test (<FAX mode> SIM 66-13)
(1) Dial pulse transmission test
1) Execute SIM 66-13 in FAX mode.
2) Execute the dial pulse mode according to the instructions on the
LCD display.
SELECT SIGNAL
1:PULSE 2:DTMF
3) Set the make time.
INPUT MAKE TIME
(0–15)
4) Select the dial to be transmitted.
Default: 0123456789#
(After deleting with the clear key, it can be set to any desired
value.)
5) Transmission is started from the line.
SEND yyPPS xxm s
1:YES 2:NO
SENDING yyPPS xxm s
SIM
Soft
SW
Initial
value
Set value
Dial
pulse
make
time
10
PPS
FAX
mode
66-13
SW67-
1 4
40ms
(14)
SW set
value: 0 15
Make time:
25 41ms
1ms
step
(Binary
input)
(2) DTMF signal transmission level adjustment
1) Execute SIM 66-13 in the FAX mode.
2) Execute the DTMF mode according to the instructions on the
LCD display.
SELECT SIGNAL
1:PULSE 2:DTMF
3) Select the signal transmission level.
The signal transmission level is classified into two groups: the
high group, and the low group.
Transmission can be made with either of default and the soft
SW set value.
SELECT HIGH LEVEL
1:DEFAULT 2:SOFT SW.
SELECT LOW LEVEL
1:DEFAULT 2:SOFT SW.
4) The transmission level can be set when the following menu is
displayed on the LCD. (et value 1 = 0.5dB change)
INPUT VALUE
(0–15)
(This value is returned to the original value when the simulation
mode is canceled.)
5) Select the dial signal to be transmitted.
Default: 0123456789#
(After deleting with the clear key, it can be set to any desired value.)
6) Start transmission from the line.
H:xx L:yy
1:YES 2:NO
SENDING DTMF
xx: High group soft SW set value
yy: Low group soft SW set value
SIM
Soft
SW
Initial
value
Set value
DTMF
trans-
mission
level
High
group
(FAX
mode)
66-13
(Test
only)
SW53-
1 4
3.5dB
(7)
SW set
value: 0
15
Transmis-
sion level:
0 7.5db
0.5ms
step
(Binary
input)
Low
group
SW53-
5 8
3.5dB
(7)
AR-FX2