Specifications

[6] SOFTWARE SWITCH DESCRIPTIONS
1. Software switch changing procedure
1) Execute SIM 66-01 in the FAX mode.
2) Select “1.YES” in the FAX soft SW setup.
3) FAX soft SW No. input
XX (2 digits: 10-keyinput) + START key
4) Select “1.YES” in the Soft SW content check.
5) Press the bit No. to be changed, and the bit No. is high-
lighted.
6) Select “1.YES” in the confirmation menu of change.
7) The change is completed, and the display returns to the soft
SW select menu.
2. Details
When a value which is outside of the specified range is entered, the
item is automatically set to the default.
Never change the switches which are “Reserved”.
SW
NO.
Data
NO.
Item Switch selection and contents of functions Initial value
User
program
No.
Remark
SW1 1 Image quality
priority selection
Used to select the image quality setup (LED) among
“Ultra fine”, “Super fine”, “Fine”, and “Standard” after
pressing C/A key or in auto clear procedure
Standard 0 151
2 0
3 Reserved 0
4 Auto/manual
default setup
Used to select Auto/Manual reception mode when turning
on the power. (When no external telephone is connected,
do not select Manual. However, setup is possible and
reception can be made by on-hook.
Auto
reception
0 Manual can be
set only when
an external
telephone is
connected.
5 Send request
protection
Used to set enable/disable of the confidential function
(inhibition against erroneous transmission) during send
request communication (remote transmission).The
confidential function is performed with identification of the
code numbers which is registered in the machine and
the other party machine. Sender No. Send request
allow No. or system No. ID No.
Protected 0 118
6 Reduction
send mode
Used to set whether the transmitted document is
received in reduction size or both ends of recording
paper are cut when the transmitted document width is
greater than the recording paper width.
Reduction 0 124
7 Sent document
print in
memory send
error
Used to set Print/Not print part of the sent document in
the transmission result table in case of a memory
transmission error. For confidential transmission,
however, no output is made.
Print 0 138
8 Reserved 0
SW1 Bit No. 1 2
Standard 0 0
Fine 0 1
Super fine 1 0
Ultra fine 1 1
1: Manual reception 0: Auto reception
1: Not protected 0: Protected
1: Standard 0: Reduction
1: Not print 0: Print
AR-FX2