Specifications

SW
NO.
Data
NO.
Item Switch selection and contents of functions Initial value
User
program
No.
Remark
SW21 1 Interval
between the
end of a
communication
and the next
call
Used to set the time interval between the end of a
communication and a call for the next communication.
1 sec 0
2 0
3 0
4 0
5 0
6 0
7 0
8 1
SW22 1 Reserved 0
2 Reserved 1
3 Reserved 1
4 Reserved 0
5 Reserved 0
6 Reserved 1
7 Reserved 1
8 Reserved 1
SW23 1 Reserved 0
2 Reserved 1
3 Reserved 1
4 Reserved 1
5 Reserved 1
6 Reserved 0
7 Reserved 1
8 Reserved 0
SW24 1 Reserved 1
2 Reserved 0
3 Reserved 0
4 Reserved 0
5 Reserved 0
6 Received
document
output setup
Used to set whether all received documents are
outputted at a time after completion of reception or each
document is outputted every time when it is received.
Each
document
is
outputted
every
time
when it
is
received.
0
7 Reserved 0
8 Auto reduction
print
Used to set whether auto reduction print is made or not
when the received document size is greater than the
fixed size and smaller than the length of auto reduction
line number setup. When auto reduction print is set to
Enable, larger or smaller documents are printed in the
fixed size.
Enable 1 132
SW21 Bit No. 1 2 3 4 5 6 7 8
Set range
0 255 sec in the increment of 1
sec (Binary input)
1: All received
documents are outputted
at a time after
completion of
0: Each document is
outputted every time
when it is received.
1: Enable 0: Disable
AR-FX2
6 10