Service manual

AR-M351U/M451U, AR-M355U/M455U SIMULATION 9 - 1
[9] SIMULATION
1. Outline and purpose
The simulation has the following functions to grasp the machine
operating status, identify the trouble position and causes in an ear-
lier stage, and make various setups and adjustments speedily for
improving the serviceability of the machine.
1) Various adjustments
2) Setup of specifications and functions
3) Canceling troubles
4) Operation check
5) Various counters check, setup, and clear
6) Machine operating status (operation history) data check, clear
7) Transfer of various data (adjustments, setup, operations,
counters)
The operating procedures and the displays differ depending on the
form of the operation panel of the machine.
2. Code-type simulation
A. Operating procedures and operations
Entering the simulation mode
1) Copy mode key ON
Program key ON
Asterisk (*) key ON
CLEAR key ON
Asterisk (*) key ON
Ready for input of
a main code of simulation
2) Entering a main code with the 10-key
START key ON
3) Entering a sub code with the 10-key
START key ON
4) Select an item with the scroll key and the item key.
5) The machine enters the mode corresponding to the selected
item.
Press START key or EXECUTE key to start the simulation
operation.
To cancel the current simulation mode or to change the main
code and the sub code, press the user setup key.
Canceling the simulation mode to return to the normal mode
1) Press CA key.