Service manual

AR-M351U/M451U, AR-M355U/M455U SIMULATION 9 - 12
Operation/Procedure
The LCD is changed as shown below. (The contrast changes
every 2sec from the current level to MAX
MIN the current
level. During this period, each LED is lighted.
Operation/Procedure
1) Select the number corresponding to the target of operation
check with 10-key.
2) Press [START] key.
The load selected in procedure 1 performs ON/OFF operation.
Press [CUSTOM SETTINGS] key to stop the operation of the
load.
The ON/OFF operation of the selected heater lamp is
repeated every 500ms five times.
Operation/Procedure
1) Select the number corresponding to the target of operation
check with 10-key.
2) Press [START] key.
The load selected in procedure 1 turns ON for 10sec.
Press [CUSTOM SETTINGS] key to stop the operation.
The copy lamp or CIS is turned on for 10sec and turned off.
NOTE: CIS: only when the DSPF is installed.
Operation/Procedure
1) Select the number corresponding to the target of operation
check with 10-key.
2) Press [START] key.
The load selected in procedure 1 operates.
Press [CUSTOM SETTINGS] key to stop the operation.
5
5-1
Purpose Operation test/Check
Function
(Purpose)
Used to check the operation of the display, LCD in
the operation panel, and control circuit.
Section Operation (Display/Operation key)
Item Operation
After 6.0sec Press [CUSTOM SETTINGS] key,
and the operation is stopped.
5-2
Purpose Operation test/Check
Function
(Purpose)
Used to check the operation of the heater lamp
and the control circuit.
Section Fixing (Fusing)
Item Operation
1 HL1 (LOWER) Heater lamp 1 (Lower)
2 HL2 (UPPER) Heater lamp 2 (Upper)
Press [START] key, and the
operation is started.
Press [CUSTOM SETTINGS] key, and
the operation is stopped.
The operation is repeated the specified
number of times before stopping.
SIMULATION 5-1
SIMULATION 5-1
SIMULATION 5-2
HEATER LAMP TEST. SELECT 1-2, AND PRESS START.
1.HL1(LOWER)
2.HL2(UPPER)
2
SIMULATION 5-2
HEATER LAMP TEST. EXECUTING···.
1.HL1(LOWER)
2.HL2(UPPER)
2
5-3
Purpose Operation test/Check
Function
(Purpose)
Used to check the operation of the scanner lamp
and the control circuit.
Section Optical (Image scanning)
Item Operation
Press [START] key, and the operation
is started.
Press [CUSTOM SETTINGS] key, and
the operation is stopped after 10sec.
6
6-1
Purpose Operation test/Check
Function
(Purpose)
Used to check the operation of the paper transport
system loads and the control circuit.
Section Paper transport (Discharge/Switchback/Transport)
Item Operation
1 MSWPR MSW power relay signal
2 HLPR Heater power relay
3 DCPR DC power relay
4 MM Main motor
5 DM Drum motor
6 POM_FW Paper exit motor forward rotation
7 POM_RV Paper exit motor reverse rotation
8 CPFC Paper feed clutch
9 RRC Resist roller clutch
10 TRC Transport roller clutch
11 FGS_FIN Finisher gate solenoid
12 LUM Tray 1 lift-up motor
13 TRC_DSK Desk clutch sync signal
14 PSPS Separation pawl solenoid
15*1 MCM MP drive motor control signal
16*1 MCPCL MP tray paper feed clutch signal
17*1 MCFCL MP tray transport clutch signal
SIMULATION 5-3
COPY LAMP TEST. SELECT 1-2, AND PRESS START.
1.COPY LAMP
2.CIS
1
SIMULATION 5-3
COPY LAMP TEST. EXECUTING···.
1.COPY LAMP
2.CIS
1