Service manual

AR-M351U/M451U, AR-M355U/M455U SIMULATION 9 - 13
*1: Displayed when OPTION of multi-purpose only.
*2: Displayed when manual feed OPTION is added.
Operation/Procedure
1) Select the number corresponding to the target of operation
check with 10-key.
2) Press [START] key.
The load selected in procedure 1 operates.
Press [CUSTOM SETTINGS] key to stop the operation.
Operation/Procedure
1) Select the number corresponding to the operating condition of
aging with 10-key.
The combined mode of 0 - 6 mode and 10, 20, or 30 mode can
be set.
In that case, the number corresponding to one of 0 - 6 mode
and the number corresponding to one of 10, 10, and 30 mode
are added and the sum number is entered.
2) Press [START] key.
The condition selected in procedure 1) is set.
The setting of this simulation is kept valid until the power is turned
off.
18*1 MCLUM MP tray lift-up motor signal
19*2 MPFS Manual paper feed solenoid signal
20*2 MPFC Manual paper feed clutch signal
21*2 MSS Manual paper feed gate solenoid
Press [START] key, and the
operation is started.
Press [CUSTOM SETTINGS] key, and the
operation is stopped immediately or after
repeating the operation several times.
6-2
Purpose Operation test/Check
Function
(Purpose)
Used to check the operations of each fan motor
and its control circuit.
Section Other
Item Operation
1 Fan motor high speed
2 Fan motor low speed
3 Cooling fan motor (Controller/HDD)
Press [START] key, and the operation
is started.
Press [CUSTOM SETTINGS] key, and
the operation is stopped.
SIMULATION 6-1
FEED OUTPUT CHECK. SELECT 1-22, AND PRESS START.
1.MSWPR 2.HLPR 3.DCPR 4.MM 5.DM 6.DSB_FW
7.DSB_RV 8.CPFC 9.RRC 10.TRC 11.FGS_FIN
12.LUM 13.TRC_DSK 14.PSPS
15.MCM 16.MCPCL 17.MCFCL 18.MCLUM
19.MPFS 20. MPFC 21.MSS 22.MSWS
2
SIMULATION 6-1
FEED OUTPUT CHECK. EXECUTING
...
.
1.MSWPR 2.HLPR 3.DCPR 4.MM 5.DM 6.DSB_FW
7.DSB_RV 8.CPFC 9.RRC 10.TRC 11.FGS_FIN
12.LUM 13.TRC_DSK 14.PSPS
15.MCM 16.MCPCL 17.MCFCL 18.MCLUM
19.MPFS 20.MPFC 21.MSS 22.MSWS
2
SIMULATION 6-2
FAN MOTOR CHECK. SELECT 1-3, AND PRESS START.
1.FMHi
2.FMLo
3.CFM-ICU/HDD
2
SIMULATION 6-2
FAN MOTOR CHECK..
2.FMLo
2
7
7-1
Purpose Setting
Function
(Purpose)
Used to set the operating conditions of aging.
Section
Item Operation
0 NO MISS FEED DETECTION No jam detection
1 AGING Aging mode
2 AGING/NO MISS FEED
DETECTION.
No jam detection, aging
mode
3 AGING/NO MISS FEED
DETECTION/NO WARM UP/
NO TEMPERATURE
CONTROL.
No jam detection/ no warm-
up/ no fusing temperature
control, aging mode
4 NO WARM UP. No warm-up
5 AGING/INTERVAL. Intermittent aging mode
6 AGING/INTERVAL/NO MISS
FEED DETECTION.
No jam detection
intermittent aging mode
+10 NO PROCESS UNIT CHECK. Above +10: No process unit
(including the developing
unit) detection
+20 NO SHADING. Above +20: No shading
+30 NO PROCESS UNIT CHECK/
NO SHADING.
Above +30: No process unit
detection /no shading
Press [START] key to start registration and operation.
The operation mode is kept until the power is turned off or setting is made again.
SIMULATION 7-1
AGING TEST SETTING. SELECT 0-36, AND PRESS START.
0.NO MISS FEED DETECTION
1.AGING
2.AGING/NO MISS FEED DETECTION.
3.AGING/NO MISS FEED DETECTION/
NO WARM UP/NO TEMPERATURE CONTROL.
4.NO WARM UP.
5.AGING/INTERVAL.
6.AGING/INTERVAL/NO MISS FEED DETECTION.
+10:NO PROCESS UNIT CHECK.
+20:NO SHADING.
+30:NO PROCESS UNIT CHECK/NO SHADING.
2