Service manual

AR-M351U/M451U, AR-M355U/M455U SIMULATION 9 - 15
Operation/Procedure
1) Enter the number corresponding to the adjustment item with
10-key.
2) Press [START] key.
3) Enter the adjustment value with 10-key.
4) Press [START] key.
(The set value is stored, and the output corresponding to the
set value is outputted for 30sec.)
Press [CUSTOM SETTINGS] key to stop the operation.
(The main charger grid output voltage adjustment and output
check can be made in each print mode.)
Operation/Procedure
1) Enter the number corresponding to the adjustment item with
10-key.
2) Press [START] key.
3) Enter the adjustment value with 10-key.
4) Press [START] key.
(The set value is stored, and the voltage corresponding to the
set value is outputted for 30sec.)
Press [CUSTOM SETTINGS] key to stop the operation.
(The transfer output voltage adjustment and output check can be
made in each print mode.)
Operation/Procedure
1) Enter the number corresponding to the adjustment item with
10-key.
2) Press [START] key.
3) Enter the adjustment value with 10-key.
4) Press [START] key.
(The set value is stored, and the voltage corresponding to the
set value is outputted for 30sec.)
Press [CUSTOM SETTINGS] key to stop the operation.
(The transfer output voltage adjustment and output check can be
made in the transfer belt cleaning mode.)
8-2
Purpose Adjustment/Operation test/Check
Function
(Purpose)
Used to check and adjust the operation of the
main charger grid voltage in each printer mode
and the control circuit.
Section Image process (Photoconductor/Developing/
Transfer/Cleaning)
Item
Set
range
Default
AR-
M351U/
M355U
AR-
M451U/
M455U
1 AUTO Auto mode 200 - 900 615 645
2 CHARACTER Text mode 645 645
3 MIX Text/Photo mode
4 PHOTO Photo mode
5 PRINTER Printer mode
6 FAX FAX mode
Press [START] key. Press [CUSTOM SETTINGS] key.
Press [START] key. Press [CUSTOM SETTINGS] key.
Or after 30sec output.
8-6
Purpose Adjustment/Operation test/Check
Function
(Purpose)
Used to check and adjust the operation of the
transfer voltage and the control circuit.
Section Image process (Photoconductor/Developing/
Transfer/Cleaning)/Transfer
SIMULATION 8-2
1
MAIN GRID SETTING. SELECT 1-6, AND PRESS START.
1.AUTO 645 2.CHARACTER 645
3.MIX 645 4.PHOTO 645
5.PRINTER 645 6.FAX 645
SIMULATION 8-2
MAIN GRID SETTING. INPUT VALUE, AND PRESS START.
1.AUTO (200-900)
645
SIMULATION 8-2
MAIN GRID SETTING. EXECUTING···.
1.AUTO
645
Item
Set
range
Default
AR-M351U/
M355U
AR-M451U/
M455U
1 FRONT Long side
print mode
0 - 620 220 267
2 BACK Back side
print mode
267 310
Press [START] key. Press [CUSTOM SETTINGS] key.
Press [START] key. Press [CUSTOM SETTINGS] key.
Or after 30sec output.
8-17
Purpose Operation test/Check
Function
(Purpose)
Used to check and adjust the operation of the
transfer voltage and the related circuit. (Transfer
belt cleaning mode)
Section Image process (Photoconductor/Developing/
Transfer/Cleaning)
Item Operation
Item
Set
range
Default
AR-
M351U/
M355U
AR-
M451U/
M455U
1 SHF FRONT AC component 0 - 240 120 160
2 SHV BACK AC component 0 - 240 120 160
3 THV- DC component 0 - 1250 780 780
SIMULATION 8-6
1
THV+ SETTING. SELECT 1-2, AND PRESS START.
1.FRONT 267
2.BACK 310
SIMULATION 8-6
THV+ SETTING. INPUT VALUE, AND PRESS START.
1.FRONT(0-620)
267
SIMULATION 8-6
THV+ SETTING. EXECUTING···.
1.FRONT
267