AR-M351U/M451U, AR-M355U/M455U SIMULATION 9 - 28
Operation/Procedure
1) Press [START] key.
The developing motor rotates for 2 min and the toner concen-
trations sensor makes sampling of toner concentration 16
times, and the detection level is displayed.
After the developing motor stops, the average value of toner
concentration sampling is set as the reference toner concen-
tration level.
NOTE: When the above operation is interrupted on the way, the
reference toner concentration level is not set. Also when
error code of EE-EL or EE-EU is displayed, the reference
toner concentration level is not set normally.
(Default: 118)
2) The humidity near the developing tank at the developing
adjustment is registered.
Operation/Procedure
1) Select the number corresponding to the auditor mode with 10-
key.
2) Press [START] key.
(Default: 1)
Operation/Procedure
1) Select the number corresponding to the counter to be set with
10-key.
2) Press [START] key.
3) Select the count mode with 10-key.
4) Press [START] key.
Set the count-up (1 or 2) for A3/WLT paper.
(Select the target counter.)
(Count-up)
Operation/Procedure
1) Select the number corresponding to the destination with 10-
key.
2) Press [START] key.
After completion of setting, the machine is automatically reset.
25-2
Purpose Setting
Function
(Purpose)
Used to make the initial setting of toner
concentration when replacing developer.
Section Image process (Photoconductor/Developing/
Transfer/Cleaning)
Press [START] key. Press [CUSTOM SETTINGS] key, and the
operation is stopped immediately or after 2 min.
26
26-3
Purpose Setting
Function
(Purpose)
Used to set the specifications of the auditor.
Setting must be made according to the auditor use
conditions.
Section Auditor
Item Specifications
1 P10 Built-in auditor mode
2 VENDOR Coin vendor mode
3 OTHERS Other
4 VENDOR-EX Coin vendor mode (without temporarily
charge)
5 VENDOR-EX+ Coin vendor mode (without temporarily
charge) + Document filing function
enable
SIMULATION 25-2
AUTOMATIC DV ADJUSTMENT. PRESS START.
HUMIDITY AREA : 70.0 - 72.5
TEMPERATURE AREA: 70.0 - 72.5
DEVE REFERENCE : 118
SIMULATION 25-2
AUTOMATIC DV ADJUSTMENT. EXECUTINGยทยทยท.
HUMIDITY AREA : 70.0 - 72.5
TEMPERATURE AREA: 70.0 - 72.5
DEVE REFERENCE : 118
26-5
Purpose Setting
Function
(Purpose)
Used to set the count mode of the total counter
and the maintenance counter.
Item Specifications Counter
1 TOTAL COUNTER Total counter
2 MAINTENANCE (DRUM)
COUNTER
Maintenance counter/ OPC
drum counter
3 DV COUNTER Developer counter
1 1 COUNT UP 1 count-up
2 2 COUNT UP 2 count-up Default
Press [START] key. Press [CUSTOM SETTINGS] key.
26-6
Purpose Setting
Function
(Purpose)
Used to set the specifications (paper, document
detection, etc.) of the destination.
Item Specifications Destination
1 USA United States of America
2 CANADA Canada
3 INCH Inch series EX
4 JAPAN Japan
5 AB_B AB series B5
6 EUROPE Europe
7UK UK
8 AUSTRALIA Australia
9 AB_A AB series A5
10 CHINA China
SIMULATION 26-3
AUDITOR SETUP. SELECT 1-3, AND PRESS START.
1.P10
2.VENDOR
3.OTHERS
4.VENDOR-EX
5.VENDOR-EX+
1
SIMULATION 26-5
1
A3(LEDGER) COUNT UP MODE SETTING. SELECT 1-3, AND PRESS
START.
1. TOTAL COUNTER 1
2. MAINTENANCE(DRUM) COUNTER 1
3. DV COUNTER 1
SIMULATION 26-5
A3(LEDGER) COUNT UP MODE SETTING. SELECT 1-2, AND PRESS
START.
1. TOTAL COUNTER
(1: 1COUNT UP, 2: 2COUNT UP)
1