Service manual

AR-M351U/M451U, AR-M355U/M455U SIMULATION 9 - 45
Operation/Procedure
(Toner save operation YES/NO setting in the auto mode)
1) Select "1. AE MODE" with 1-key.
2) Press [START] key.
3) Select the number corresponding to the operation specifica-
tions with 10-key.
4) Press [START] key.
When [START] key is pressed, the adjustment value is set.
(Operation setting in the auto copy mode)
1) Select the number corresponding to the mode with 10-key.
(Select one of 2 - 4.)
2) Press [START] key.
3) Select the number corresponding to the operation mode with
10-key.
4) Press [START] key.
Select 2, and
press [START] key.
Press [START] key, or
press [CUSTOM SETTINGS] key.
46-19
Purpose Adjustment
Function
(Purpose)
Used to set the auto mode operation
specifications in each mode (copy, scan, FAX).
Item Picture quality Density
64
1
SIMULATION 46-18
GAMMA SETUP(COPIER). SELECT 0-18, AND PRESS START.
0.TRAY SELECT 1 1.PRINT START 2.EXP LEVEL 1
3.OC_AE 64 4.OC_CHARA 5.OC_MIX 64
6.OC_PHOTO 64
7.SPF1_AE 64 8.SPF1_CHARA 64 9.SPF1_MIX 64
10.SPF1_PHOTO 64
11.SPF2_AE 64 12.SPF2_CHARA 64 13.SPF2_MIX 64
14.SPF2_PHOTO 64
15.CIS_AE 64 16.CIS_CHARA 64 17.CIS_MIX 64
18.CIS_PHOTO 64
SIMULATION 46-18
GAMMA SETUP. INPUT VALUE 0-127, AND PRESS START.
3.OC_AE
SIMULATION 46-18
GAMMA SETUP. NOW PRINTING.
SIMULATION 46-18
GAMMA SETUP(COPIER). SELECT 1-5, AND PRESS START.
(FEED TRAY)
1.TRAY1 2.TRAY2 3.TRAY3 4.TRAY4
5.BPT
Select other than 0 - 2,
and press [START] key.
Press [CUSTOM SETTINGS] key.
Press [START] key.
Press [CUSTOM SETTINGS] key,
or terminate copying.
Select 1,
and press
[START] key.
Select 0, and press [START] key.
1
SIMULATION 46-18
GAMMA SETUP(COPIER)
. SELECT 3-14, AND PRESS
START.
(EXP.LEVEL SELECT)
3.AUTO 4.1.0 5.2.0
6.3.0 7.4.0 8.5.0
9.AUTO(H) 10.1.0(H) 11.2.0(H)
12.3.0(H) 13.4.0(H) 14.5.0(H)
1 AE MODE AE mode
2 AE STOP MODE (COPIER) AE fixed mode (Copier)
3 AE STOP MODE (SCANNER) AE fixed mode (Scanner)
4 AE STOP MODE (FAX) AE fixed mode (FAX)
Mode
Set
value
Item Default
AE
mode
1 Image quality priority mode
(Normal mode)
Gamma is sharp to provide
high contrast images.
2
2 Toner consumption priority mode
Gamma is mild to provide low
contrast images.
AE
fixed
mode
0 AE fixed OFF 1 (COPIER)
0
(SCANNER/
FAX)
1 AE fixed ON
AE fixed OFF: The automatic density (exposure) control is per-
formed in real time. (The density level is changed
in real time according to the document pattern.)
AE fixed ON: The density at the lead edge of the document is
scanned, and the overall density (exposure) level
is determined according to the scanned density
level. (Overall density level fixed)
Select 2, 3, or 4 and
press [START] key.
Press [START] key, or
press [CUSTOM SETTINGS] key.
2
Select 1, and
press [START] key.
Press [CUSTOM SETTINGS] key.
SIMULATION 46-19
EXP.MODE SETUP. SELECT 1-4, AND PRESS START.
1.AE MODE 2
2.AE STOP MODE(COPIER) 1
3.AE STOP MODE(SCANNER)0
4.AE STOP MODE(FAX) 0
SIMULATION 46-19
EXP.MODE SETUP. INPUT VALUE 1-2, AND PRESS START.
1.AE MODE
1
SIMULATION 46-19
EXP.MODE SETUP. INPUT VALUE 0-1, AND PRESS START.
2.AE STOP MODE(COPIER)