Operation/Procedure
1) Enter the number corresponding to the output mode with 10-
key.
2) Press [START] key.
The output is delivered at the send level set with the soft SW.
When the number is entered during execution, the kind of signal
can be changed.
When [START] key is pressed, the voice message is sent. When
[CUSTOM SETTINGS] key is pressed, it is stopped.
Operation/Procedure
1) Select YES/NO of image memory clear with 10-key.
2) Press [START] key.
The SRAM image data management table and image data in the
Flash ROM area and HD (except for filing images) are cleared.
The processing status of image memory clear is displayed with
"+."
Operation/Procedure
1) Select the number corresponding to the output mode with 10-
key.
2) Press [START] key.
The signal is sent in the max. send level.
When the number is entered during execution, the kind of signal
can be changed.
When [CUSTOM SETTINGS] key is pressed during execution, the
operation is stopped.
66-9
Purpose Operation test/Check
Function
(Purpose)
Used to check the output operation of various
sound signals of FAX. (Used to check the
operation of the sound output IC.) An output is
sent at the send level set by the soft switch. (Only
when FAX is installed)
Section FAX
Item Operation
1 NONE Mute 11 MESSAGE 9 MESSAGE 9
2 PAUSE Pause sound 12 MESSAGE10 MESSAGE 10
3 MESSAGE1 MESSAGE 1 13 MESSAGE11 MESSAGE 11
4 MESSAGE2 MESSAGE 2 14 MESSAGE12 MESSAGE 12
5 MESSAGE3 MESSAGE 3 15 MESSAGE13 MESSAGE 13
6 MESSAGE4 MESSAGE 4 16 MESSAGE14 MESSAGE 14
7 MESSAGE5 MESSAGE 5 17 MESSAGE15 MESSAGE 15
8 MESSAGE6 MESSAGE 6 18 ALARM Alarm
9 MESSAGE7 MESSAGE 7 19 RINGER Call ring
10 MESSAGE8 MESSAGE 8 20 EXT.TEL.RINGER External TEL ring
Same
display
SIMULATION 66-9
MESSAGE OUTPUT CHECK.(SOFT SW.) SELECT 1-20, AND PRESS
START. EXECUTING···.
1.NONE 2.PAUSE 3.MESSAGE1
4.MESSAGE2 5.MESSAGE3 6.MESSAGE4
7.MESSAGE5 8.MESSAGE6 9.MESSAGE7
10.MESSAGE8 11.MESSAGE9 12.MESSAGE10
13.MESSAGE11 14.MESSAGE12 15.MESSAGE13
16.MESSAGE14 17.MESSAGE15 18.ALARM
19.RINGER 20.EXT.TEL.RINGER
2
SIMULATION 66-9
MESSAGE OUTPUT CHECK.(SOFT SW.) SELECT 1-20, AND PRESS
START. EXECUTING···.
1.NONE 2.PAUSE 3.MESSAGE1
4.MESSAGE2 5.MESSAGE3 6.MESSAGE4
7.MESSAGE5 8.MESSAGE6 9.MESSAGE7
10.MESSAGE8 11.MESSAGE9 12.MESSAGE10
13.MESSAGE11 14.MESSAGE12 15.MESSAGE13
16.MESSAGE14 17.MESSAGE15 18.ALARM
19.RINGER 20.EXT.TEL.RINGER
1
SIMULATION 66-9
MESSAGE OUTPUT CHECK.(SOFT SW.) SELECT 1-20, AND PRESS
START.
1.NONE 2.PAUSE 3.MESSAGE1
4.MESSAGE2 5.MESSAGE3 6.MESSAGE4
7.MESSAGE5 8.MESSAGE6 9.MESSAGE7
10.MESSAGE8 11.MESSAGE9 12.MESSAGE10
13.MESSAGE11 14.MESSAGE12 15.MESSAGE13
16.MESSAGE14 17.MESSAGE15 18.ALARM
19.RINGER 20.EXT.TEL.RINGER
2
Press [CUSTOM SETTINGS] key.
Press [CUSTOM SETTINGS] key.
Select other 1, and press [START] key.
Select 2, and press [START] key.
66-10
Purpose User data output/Check (Display/Print)
Function
(Purpose)
Used to clear all data of the image memory
(memory send/receive). The confidential data are
also cleared at the same time. (Only when FAX is
installed)
Section FAX
Item Data
1 YES Image memory clear is executed.
2 NO Clear is not executed.
Press [START] key to clear.
66-11
Purpose Operation test/Check
Function
(Purpose)
Used to check the output operation of FAX G3
mode 300bps. (Used to check the operation of
MODEM.) Send level: Max. (Only when FAX is
installed)
Section FAX
Item Operation
1 NO SIGNAL No signal 4 00000 00000
2 11111 11111 5 010101 010101
3 11110 11110 6 00001 00001
SIMULATION 66-10
IMAGE MEMORY CLEAR
ARE YOU SURE?
1. YES
2. NO
1
1
SIMULATION 66-10
IMAGE MEMORY CLEAR EXECUTING···.
++++++