Service manual

AR-M351U/M451U, AR-M355U/M455U SIMULATION 9 - 87
3. Other related items
(1) Simulation adjustment value/ Set value data
Each controller is provided with an EEPROM. The adjustment/set
values are collected to the MFP controller. If they are changed,
they are sent back and saved.
Data saved by the PCU PWB
MFP
CONTROLLER
ENGINE
CONTROLLER
SCANNER
CONTROLLER
LCD
Saved adjustment value send
(When the power is turned on, etc.)
When the value is changed,
it is sent and saved.
Counters Adjustment value Other
Drum rotation time counter
(Accumulated time)
Developing bias voltage value Serial number
Developer unit rotation time
counter
Cleaning mode developing bias voltage value Trouble history
Toner supply time (Block IC CHIP) Main high voltage adjustment Tray 1 size
Drum rotating time (Block IC
CHIP)
Transfer charger voltage value LCC size
Total counter Transfer belt cleaning voltage value Manual destination information
Maintenance counter Toner concentration reference value
Developing counter Density correction start set time (Developer unit) Tray 2 destination information
Drum counter Density correction rotation time (Developer tank)
Toner cartridge counter Density correction amount (Developer tank) Tray 1 paper remaining quantity data
Valid paper counter Correction execution direction, upper/lower limit
(Developer tank)
Tray 2 paper remaining quantity data
Tray 1 paper feed counter Toner concentration temperature correction (low
temperature side) correction amount
Tray 3 paper remaining quantity data
Tray 2 paper feed counter Toner concentration temperature correction (low
temperature side) set temperature
Tray 4 paper remaining quantity data
Tray 3 paper feed counter Toner concentration temperature correction (low
temperature side) release temperature
Final toner concentration sensor output value
Tray 4 paper feed counter Toner concentration temperature correction (high
temperature) correction amount
Toner cartridge IC CHIP destination
Manual paper feed counter Toner concentration temperature correction (high
temperature side) judgment temperature
Counter mode setting
ADU paper feed counter Toner concentration temperature correction (high
temperature side) judgment voltage
White paper exit count setting
Staple counter Toner concentration temperature correction (high
temperature side) correction value
Trouble memory mode setting
Punch counter Toner concentration temperature correction (low
temperature side) release time
Fusing operation mode (Prevention against
curl)
Main unit right-side paper exit
counter
Toner concentration temperature correction (high
temperature side) toner concentration delay time
CE mark conforming operation mode
Multi-purpose width adjustment value Maintenance cycle
Manual width adjustment value Print stop setting when developer life over
Saddle staple counter Heater lamp temperature (Center, normal control) Saddle alignment operation priority mode
Lead edge adjustment PCU SOFT SW
Led edge void set value
Rear edge void set value
Side edge setting
Print off-center adjustment value
Resist amount adjustment value
Laser power adjustment value
PPD1 sensor adjustment
Process correction inhibit allow set value
Developing bias rising correction wait time
Developing bias rising correction adjustment value
Built-in finisher jogger position adjustment
Saddle adjustment value