Service manual

AR-M351U/M451U, AR-M355U/M455U TROUBLE CODES 11 - 9
F7 01 Content FAX board EEPROM read/write error
Details EEPROM access error (read/write)
Cause EEPROM trouble
FAX PWB EEPROM access circuit
trouble
Check &
Remedy
When replacing the EEPROM, use
SIM66-4/5 (Signal send level) and
SIM66-14/15/16 (Dial test) for
adjustment. However, note that all the
soft switches are reset to the initial
values.
No need to adjust when the PWB is
replaced.
H2 00···
HL1
01···
HL2
Content Thermistor open
Fusing unit not installed
Detail Thermistor is open.
(An input voltage of 2.92V or above is
detected.)
Fusing unit not installed
Cause Thermistor trouble
Control PWB trouble
Fusing section connector
disconnection
AC power trouble
Fusing unit not installed
Check and
remedy
Check harnesses and connectors from
the thermistor to the control PWB.
Use SIM14 to clear the self diag
display.
H3 00···
HL1
01···
HL2
Content Fusing section high temperature
trouble
Detail The fusing temperature exceeds
242°C. (An input voltage of 0.27V or
above is detected.)
Fusing temperature control is started,
and 242°C is detected three or more
times continuously in sampling in the
specified interval. (Every 300msec)
Cause Thermistor trouble
Control PWB trouble
Fusing section connector
disconnection
AC power trouble
Check and
remedy
Use SIM5-2 to check the heater lamp
Blinking operation.
If the heater lamp blinks normally:
Check the thermistor and its
harness.
Check the thermistor input circuit in
the control PWB.
If the heater lamp keep lighting:
Check the AC PWB and the lamp
control circuit in the control PWB.
Use SIM14 to cancel the trouble
MAIN SUB Details
H4 00···
HL1
01···
HL2
Content Fusing section low temperature trouble
Detail The set temperature is not reached
within the specified time (3 min) after
turning on the power relay, or the
temperature does not reach 80°C
within 80 sec.
When the heater lamp is not turned off
in the specified time (3 min) from
starting warm-up, or the temperature
does not reach 80°C within 80 sec.
After completion of warm-up operation,
a temperature 50°C lower than the
temperature control level is detected 5
times continuously in sampling in the
specified interval. (every 300msec)
Cause Thermistor trouble
Heater lamp trouble
Control PWB trouble
Thermostat trouble
AC power trouble
Interlock switch trouble
Check and
remedy
Use SIM5-2 to check the heater lamp
Blinking operation.
If the heater lamp blinks normally:
Check the thermistor and its
harness.
Check the thermistor input circuit in
the control PWB.
If the heater lamp does not light:
Check for heater lamp disconnection
and thermostat disconnection.
Check the interlock switch.
Check the AC PWB and the lamp
control circuit in the control PWB.
Use SIM14 to cancel the trouble.
H5 01 Content 5-time continuous POD1 not-reaching
jam detection
Detail 5-time continuous POD1 not-reaching
jam detection
Cause A fusing section jam is not properly
removed. (Jam paper remains.)
POD1 sensor trouble, or harness
disconnection
Improper installation of fusing unit
Check and
remedy
Check jam paper in the fusing section.
(winding, etc.)
Check POD1 sensor harness, and
check the fusing unit installation.
Use SIM14 to cancel the trouble.
L1 00 Content Scanner feed trouble
Details Scanner feed is not completed within
the specified time.
Cause Scanner unit abnormality
Scanner wire disconnection
Check &
Remedy
Check scanning with SIM 1-1.
L3 00 Content Scanner return trouble
Details Scanner return is not completed within
the specified time.
Cause Scanner unit abnormality
Scanner wire disconnection
Check &
Remedy
Check scanning with SIM 1-1.
MAIN SUB Details