Service manual

AR-M351U/M451U, AR-M355U/M455U ROM VERSION-UP METHOD 12 - 3
D. In case of Result: NG
(1) Possible causes of Result: NG
There are following possible causes of Result: NG.
1) The DIP switch of write protect is not set properly.
The write protect switch of the controller PWB is not set to
the release side (lower side).
2) The FAX cable is not connected. The FAX is NG.
3) In rare cases, the ROM is broken down.
(* There are three types of ROM device: the common type for
the PCU and the scanner, the common type for BOOT and
MAIN, and the exclusive type for FAX.)
E. Turning off the power during update
When the power is turned off during the update process, though
the machine is booted, data writing cannot be assured. Retry
update as follows.
1) When the power is turned off during update process of (B.)
Retry the update procedure of (B.). If the machine is not
booted or the hard keys are not invalid (**), or retry of the
update is failed again, replace the ROMs with the spare one
of the PCU, the controller BOOT, and the scanner ROM, and
try the update procedure of (C.) for the replaced ROMs.
(** When the backlight of the display is lighted but the hard
keys are invalid, all LEDs flash.)
2) When the power is turned off during update process of (C.)
Retry updating.
F. Update window display in normal booting
After completion of updating, when the power is turned off and the
DIP switches on the back of the machine are set to the normal
side and the machine is booted, the update window is displayed
as shown below instead of the normal boot window, the PCU or
the scanner may not have been properly updated.
At that time, use Up/Down key to check the version of the PCU or
the scanner. If the version is displayed as BootMode, or if the
key operation is invalid (all the LEDs are flashing), retry updating
as follows.
1) When the key operation is possible and the version is dis-
played as BootMode
Turn off the power and retry the update procedure of (B.). At
that time, be sure to set the DIP switches properly. After
updating again, if the result is still NG, replace the ROMs with
the spare one of the PCU and the scanner ROM, and perform
the update procedure of (C.) for the replaced ROM's.
2) When the key operation is invalid
Turn off the power and replace the ROMs with the spare one
of the PCU and the scanner ROM, and perform the update
procedure of (C.) for the replaced ROMs. Be sure to set the
DIP switches properly.
G. Update process flow
The brief descriptions on the update procedures are as follows.
For turning off during update, refer to E. Turning off the power
during update.
If the update window is displayed after booting with the DIP
switches on the back of the machine set to the normal side, refer
to F. Update window display in normal booting.
If the write protect switch is not set to the release side,
data are not written into the ROM. Set the DIP switch
properly, and retry updating.
Writing is not made. Connect properly and retry writing.
Check the ROM, and retry writing. If the trouble remains,
replace the ROM.
Version Check
CONF: *********
Update completed
Write with the onboard
collective files.(B)
NO
NO
YES
YES
YES
YES
NO
NO
Reset
Setting failure ? (D.)
Result: OK ?
Boot NG?
SCN, FAX NG?