Service manual

AR-M351U/M451U, AR-M355U/M455U MAINTENANCE AND DETAILS OF EACH SECTION 7 - 2
2. Scanner / DSPF
Maintenance cycle : 200K
Check (Clean, replace, or adjust as necessary.) Clean Replace Adjust Lubricate Move position
Unit name Part name
When
calling
100K 200K 300K 400K 500K 600K 700K 800K Remark
Optical
section
Mirror/Lens/Reflector/Sensors ❍❍❍❍❍❍❍❍
Table glass/Dust-proof glass/OC ❍❍❍❍❍❍❍❍
White reference glass ❍❍❍❍❍❍❍❍
Rails ✩✩✩✩✩✩✩✩
Drive belt/Drive wire/Pulley ✕✕✕✕✕✕✕✕
DSPF Paper feed
section
Pick-up roller ❍❍❍❍❍❍❍❍Note 2
Paper feed roller ❍❍❍❍❍❍❍❍Note 2
Separation mylar lower ❍❍❍❍❍❍❍❍Note 2
Separation pad ❍❍❍❍❍❍❍❍Note 2
Transport section PS roller ❍❍❍❍❍❍❍❍
Exposure section
(Dust-proof glass)
❍❍❍❍❍❍❍❍
Paper exit
section
Paper exit roller ❍❍❍❍❍❍❍❍
Other Sensors ❍❍❍❍❍❍❍❍For cleaning, blow air.
Note 2: Replacement reference: Replace by using the SPF counter value as an indication.
Paper feed section pickup roller, paper feed roller, separation pad, separation lower mylar lower:
100K or 1 year