Service manual

AR-203E/5420/M200/M201 MAINTENANCE 11 - 1
[11] MAINTENANCE
1. Maintenance table
: Check (Clean, adjust, or replace when required.) : Clean : Replace : Adjust : Lubricate
2. Maintenance display system
Note: When developer is replaced, be sure to execute simulation No. 24-06 to reset the counter.
3. Remaining toner indication
The remaining toner indication is based on the number of revolutions of the toner motor.
The toner END indication appears when the END is detected by the toner sensor.
The remaining toner indication is a rough indication of the remaining toner quantity.
Section Parts 25K 50K 75K 100K 125K Remark
Developing Developer
DV blade
DV side seal (F/R)
DV doctor White streaks are made on the image.
Process peripheral Drum
Toner Life 8K
Remaining quantity NEAR EMPTY
About 12.5%
EMPTY
LED ON Flash
Machine Operation allowed Stop
Developer Life 25K
LED ON at 25K of the developer count.
Machine Selection is available between Not Stop and Stop by Service Simulation (SIM 26-37) Setup.
(If Stop is selected, the LED will flash and stop at 25K.)
Default: Not Stop
Clear: SIM 24-06
Maintenance LED Selection is available among 25K, 13K, 9K, 6K, 3K, and free (no lighting) with SIM 21-1.
Default: 25K
Clear: SIM 20-1
Machine Not stop.
TONER FULL
Remaining toner indication
Display for users
100%
75%
50%
25%
Lo
LOW LEVEL
100-76% 75-51% 50-26% 25-13%
12.5% or less