Service manual

AR-203E/5420/M200/M201 SIMULATION, TROUBLE CODES 10 - 18
43 04 Fusing temperature setting
in multi copy
[Function]
For 20th sheet or later in multi copy, the fusing temperature is automatically changed from the
temperature set with simulation 43-01 to the temperature set with this simulation.
When this simulation is executed, the current set code number is displayed. Enter the code
number and press [OK]/[ENTER]/[START] key to change the setting.
The cassette feed and the manual feed are controlled similarly.
[Operation]
The operation is similar to simulation 43-01.
05 Fusing temperature setup in
duplex copy (AR-M201 only)
[Function]
In the case of duplex copy, the shift temperature set with this simulation is applied to the fusing
temperature.
When this simulation is executed, the current set code number is displayed.
Enter the desired code number and press [OK]/[ENTER]/[START] key to save the setting.
[Operation]
The operation is similar to simulation 26-02.
14 Fusing start temperature
setting
[Function]
When this simulation is started, the currently set code number is displayed.
Press [ ] [ ] key (or [Numeric] key or [ ] [ ] key for the AR-M200/M201) to switch the set-
ting, and press [OK]/[ENTER]/[START] key to save it to the EEPROM. The machine goes to the
sub code entry standby mode.
[Operation]
The operation is similar to simulation 43-01.
Main
code
Sub
code
Contents Details of function/operation
Code Set temperature (°C) Remark
0 165
1 170
2 175
3 180
4 185
5 190
6 195
7 200
Mode
Display item
(AR-M200/M201)
Display lamp
(AR-203E/5420)
Default
Main cassette paper feed & 2nd
cassette paper feed
TRAY1 AE mode lamp 3
Manual paper feed MFT TEXT mode lamp 3
Main cassette paper feed & 2nd
cassette paper feed (small-size)
TRAY1 SH PHOTO mode lamp 1
Manual paper feed (small-size) MFT SH AE mode lamp
TEXT mode lamp
1
Code Shift temperature (°C) Remark
0 ±0 Default
1–8
2–6
3–4
4–2
Code Shift temperature (°C) Remark
0
6+2
7+4
8+6
9+8
Code Set temperature (°C) Remark
0 160
1 165
2 170
3 175
4 180
5 185
Code Set temperature (°C) Remark
6 190
7 195 Default
8 200
9 205
10 210