E
• Wheninstalling,removingormovingthemonitor,ensurethatthisiscarriedoutbyatleast6people.
• Besuretouseawall-mountbracketdesignedordesignatedformountingthemonitor.
• Thismonitorisdesignedtobeinstalledonaconcretewallorpillar.Reinforcedworkmightbenecessaryforsomematerials
suchasplaster/thinplasticboard/woodbeforestartinginstallation.
Thismonitorandbracketmustbeinstalledonawallwhichcanendureatleast4timesormoretheweightofthemonitor.
Installbythemostsuitablemethodforthematerialandthestructure.
• ToattachaVESA-compliantmountingbracket,useM6screwsthatare5/16inch(8mm)to3/8inch(10mm)longerthanthe
thicknessofthemountingbracket.
• Whenmovingthemonitor,besuretoholditwiththehandles,theunitbottomandthesideofunit.DonotholdtheLCDpanel
orcorners.Thismaycauseproductdamage,failure,orinjury.
• Aftermounting,pleasecarefullyensurethemonitorissecure,andnotabletocomeloosefromthewallormount.
• DonotuseanyscrewholesotherthanVESAholesforinstallation.
n
Removing the temporary stand used in the package for transportation
Caution
• Thetemporarystandusedinthepackagefortransportationisonlyforusewiththismonitor.Donotuseitforanyother
devices.
1. Spread a soft thick cloth (such as a blanket) on a stable level surface on which the entire monitor can be placed, and
place the monitor on it with the screen facing down.
2. Remove the stand xing screws and then remove the stand.
3. Attach the cover (supplied) onto the back of the monitor.
Secureusing2coverscrews(M4withwashers)(supplied).
Cover screws
(M4 with washers)
(supplied)
Cover screws
(M4 with washers)
(supplied)
Model PN-E802
Powerrequirement AC100V-240V,3.1A,50/60Hz
Operatingtemperature
*
32°Fto104°F(0°Cto40°C)
Operatinghumidity 20%to80%(nocondensation)
Powerconsumption(Maximum) 265W[WhenPN-ZB01(optional)isattached:270W]
Dimensions(excludingprotrusions) inch(mm)
Approx.73-9/16(W)x4-13/16(D)x43-1/16(H)(1869x123x1094)
Weight lbs.(kg) Approx.174.2(79)(excludingthetemporarystandusedinthepackage
fortransportation)
[PN-ZB01(optional):Approx.1.102(0.5)]
* Temperatureconditionmaychangebysettingupcondition.
TemperatureconditionmaychangewhenusingthemonitortogetherwiththeoptionalequipmentsrecommendedbySHARP.Insuchcases,
pleasecheckthetemperatureconditionspeciedbytheoptionalequipments.
Asapartofourpolicyofcontinuousimprovement,SHARPreservestherighttomakedesignandspecicationchangesforproductimprovement
withoutpriornotice.Theperformancespecicationguresindicatedarenominalvaluesofproductionunits.Theremaybesomedeviationsfrom
thesevaluesinindividualunits.
Specications
Mounting Precautions (For SHARP dealers and service engineers)