[13] Procedure L : RELAY TEST
1. Disconnect the power supply cord, and then remove outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. Disconnect the leads to the primary of the power transformer.
5. Ensure that these leads remain isolated from other components and oven chassis by using insulation tape.
6. After that procedure, re-connect the power supply cord.
7. Remove the outer case and check voltage between the normal open terminal of the relay RY1 and the normal open terminal of the relay RY2 on
the control unit with an A.C. voltmeter.
The meter should indicate 120 volts, if not check oven circuit.
RY1 and RY2 Relay Test
These relays are operated by D.C. voltage
Check voltage at the relay coil with a D.C. voltmeter during the microwave cooking operation.
DC. voltage indicated ....................... Defective relay.
DC. voltage not indicated ................. Check diode which is connected to the relay coil. If diode is good, control unit is defective.
8. Disconnect the power supply cord and then remove outer case.
9. Open the door and block it open.
10.Discharge high voltage capacitor.
11.Reconnect all leads removed from components during testing.
12.Re-install the outer case (cabinet).
13.Reconnect the power supply cord after the outer case is installed.
14.Run the oven and check all functions.
[14] Procedure M : DEFROST TEST
WARNING: The oven should be fully assembled before following procedure.
1. Place one cup of water in the center of the turntable tray in the oven cavity.
2. Close the door, touch the “DEFROST“ pad once. And then touch the number pad 2.
3. Touch the number pad 5 and then touch the start pad.
4. The oven is in Defrost cooking condition.
5. The oven will operate as follows.
6. If improper operation is indicated, the control unit is probably defective and should be checked.
RELAY SYMBOL OPERATIONAL VOLTAGE CONNECTED COMPONENTS
RY1 Approx. -12V D.C. Oven lamp / Turntable motor / Cooling fan motor
RY2 Approx. -11V D.C. Power transformer
MENU 1ST STAGE 2ND STAGE 3RD STAGE
Steaks/Chops LEVEL TIME LEVEL TIME LEVEL TIME
0.5lb 70% 17sec. 60% 27sec. 30% 40sec.
G2G1
MINUTE
PLUS
DEFROSTSOFTEN
POWER
LEVEL
REHEATWARM
COOK
MELT
POPCORN
TIMER
CLOCK
9
3
6
5
2
8
0
G3 G4 G5 G6 G7 G8
G9
G10
G11
G12
1
4
7
START
STOP
CLEAR
Pin NO. G12
Pin NO. G1
Key unit ribbon cable
Key unit (Membrane Switch) front view