Service manual

– 11 –
CD-M8000W/CP-M8000
Test Stage Frequency Frequency
Display
Setting/
Adjusting
Parts
Instrument
Connection
CD SECTION
AM IF/RF
Signal generator: 400 Hz, 30%, AM modulated
*1. Input: Antenna Output: TP302
*2. Input: Antenna Output: TP301
TUNER SECTION
fL: Low-range frequency
fH: High-range frequency
AM IF 450 kHz 1,602 kHz T351 *1
AM Band 531 kHz (fL): T306 *2
Coverage 1.1 ± 0.1 V
AM Tracking 990 kHz 990 kHz (fL): T303 *1
*1. Input: Antenna Output: TP301
*2. Input: Antenna Output: Speaker Terminal
FM IF
Signal generator: 10.7 MHz, FM modulated
FM RF
Signal generator: 1 kHz, 40 kHz dev., FM modulated
FM Band 87.50 MHz T301(fL): *1
Coverage 3.4 V ± 50 mV
FM RF 98.00 MHz 98.00 MHz L312 *2
(10-30 dB)
Test Stage Instrument
Connection
Frequency Frequency
Display
Setting/
Adjusting
Point
Figure 11-1 ADJUSTMENT POINTS
Figure 11-2
Items adjusted automatically
(1) Offset adjustment (The offset voltage between the head
amplifier output and the VREF reference voltage is
compensated inside the IC.)
* Focus offset adjustment
* Tracking offset adjustment
(2) Tracking balance adjustment (waveform drawing
Fig. 11-2 EFBL)
(3) Gain adjustment (The gain is compensated inside the IC
so that the loop gain at the gain crossover frequency will
be 0 dB.)
* Focus gain adjustment
* Tracking gain adjustment
Adjustment
Since this CD system incorporates the following automatic
adjustment functions, readjustment is not needed when
replacing the pickup. Therefore, different PWBs and pickups
can be combined freely.
Each time a disc is changed, these adjustments are
performed automatically. Therefore, playback of each disc
can be performed under optimum conditions.
IC301
AM IF
FM IF
FM RF
T303
T306
T302
L312
AM
TRACKING fL
AM BAND
COVERAGE fL
T301
T351
FM BAND
COVERAGE fL
MAIN PWB
CNP301
AM LOOP
ANTENNA
SO301
FM ANTENNA
TERMINAL
TP302
R357
C393
TP301
T
T
EFBL
FDO
TE
Stopped
CH1=500 mV
DC 10:1
CH2=200 mV
DC 10:1
CH3=1 V
DC 10:1
500 ms/div
(500 ms/div)
NORM:20 kS/s
1
2
3
=Record Length=
Smoothing : ON CH1 : 0.000 V
CH2 : 0.000 V
Main : 100 K
Zoom : 2 k
Mode : SINGLE
Type : EDGE CH1
Delay : 0.0 ns
Hold off : 0.2 µs
CH3 : 0.00 V
CH4 : 0.00 V
BW : FULL
=Trigger==Filter= =Offset=
CH2
v/DIV
200 mV
1999/04/05 20:26:47
IF 10.7 MHz 98 MHz T302 *1
(Turn the
core of trans-
former T302
fully counter-
clock wise)
Test Stage Instrument
Connection
Frequency Frequency
Display
Setting/
Adjusting
Point
*1. Input: Antenna Output: TP301
CD ERROR CODE DESCRIPTION
Error Explanation
01
When Pickup set inner position, inner switch
cannot detect 'ON' level for 10 secs.
When tray moves to Open/Close, Open/Close switch
10*
cannot detect 'ON' level for 7 secs.
When disc table rotate to target position.
Clamp switch cannot detect 'ON' level for 7 secs.
When disc table set to Disc1 position for 1 st time,
11* "CLAMP SW", "DISC NO SW" and "OPEN/CLOSE"
cannot detect 'ON' level for 14 secs.
31
When it changes to CD function, DSP cannot read
initial data.
* 'CHECKING'
If Error is detected, 'CHECKING' will be display instead of 'ER-
CD**' display. 'ER-CD**' display will only be display when