8009861/WA65/2012-06-12 © SICK AG • Industrial Safety Systems • Germany • All rights reserved 37
Subject to change without notice
Configurable functions
Physical resolution Reduction
Effective
resolution
Maximum size of
movable objects
14 mm 1 beam 22 mm 10 mm
2 beams 30 mm 18 mm
3 beams 37 mm 25 mm
2
0 mm
1
beam 30 mm 14 mm
2 beams 40 mm 24 mm
3 beams Not possible
The reduced resolution function can only be used with the C4000 Advanced with a phy-
sical resolution of 14 mm and 20 mm.
The first beam of the light curtain (close to the 7Csegment display) must not be inter-
rupted. Otherwise, the safety light curtain will change to red.
The system response time does not change under reduced resolution.
You cannot combine the function Reduced resolution with the function Floating
blanking with partial object monitoring (see page 32).
With reduced resolution, the 7Csegment display indicates as soon as sender and re-
ceiver are aligned.
Check the minimum distance!
The minimum distance required under reduced resolution depends on the effective
resolution.
If required, recalculate the minimum distance and readjust it on the machine.
Example: – physical resolution 14 mm
resolution reduced by 1 beam
effective resolution 22 mm
Calculate the minimum distance with a resolution of 22 mm. (See page 40.)
Mark the effective resolution on the information label “Operation with reduced
resolution or blanking …” on the related sender and receiver.
Warning: During operation with “Reduced resolution” or “Blanking” the minimum
distance that corresponds to the modified resolution is to be observed.
Physical resolution
Resolution modified to:
(please mark)
14 mm
20 mm
30 mm
40 mm
Reduction
Effective resolution/Minimum object size
1 beam
22 mm
30 mm
50 mm
70 mm
2 beams
30 mm
40 mm
70 mm
100 mm
3 beams
37 mm
50 mm
90 mm
130 mm
n beams
mm
mm
mm
mm
4034160
Device symbol C4000 Host (receiver), context menu Configuration draft, Edit, file card
Host or Guest for the related system, option Reduced resolution. Here you can adjust the
effective resolution in millimetres directly.
Tab.
13
:
Effective resolution
and maximum size of moving
objects under reduced
resolution
Notes
WARNING
Fig.
21
:
Marking the effective