Operating instructions

Chapter 11 Operating Instructions
C4000 Standard/Advanced
76 © SICK AG • Industrial Safety Systems • Germany • All rights reserved 8009861/WA65/2012-06-12
Subject to change without notice
Technical specifications
Minimum Typical Maximum
External device monitoring (EDM)
i
nput
Input voltage
17)
HIGH (inactive) 11 V 24 V 30 V
Input current HIGH 6 mA 10 mA 20 mA
Input voltage
17)
LOW (active) –30 V 0 V 5 V
Input current LOW –2.5 mA 0 mA 0.5 mA
Contactors
Permissible dropout time 300 ms
Permissible pick-up time 300 ms
Control input (reset button)
Input voltage
1
7)
HIGH (active) 11 V 24 V 30 V
Input current HIGH 6 mA 10 mA 20 mA
Input voltage
17)
LOW (inactive) –30 V 0 V 5 V
Input current LOW –2.5 mA 0 mA 0.5 mA
Operation time control switch
input
Devices with firmware V3.36
50 ms
Operation time control switch
input
Devices with firmware < V3.36
200 ms
Output Reset required PNP semiconductors, short-circuit protected
18)
24 V lamp output 4 W/0.2 A
Switching voltage HIGH (active) 15 V 24 V 28.8 V
Switching voltage LOW
(inactive)
High resistance
Signal output (ADO) PNP semiconductors, short-circuit protected
18)
Switching voltage HIGH (active) U
V
4.2 V 24 V U
V
Switching voltage LOW
(inactive)
High resistance
Switching current 0 mA 100 mA
Emergency stop/bypass
Changeover time 2 s
Latency time 200 ms
Cable resistance 30
Cable capacitance 10 nF
Teach-in key-operated switch/
switch for deactivating the
blanking
Cable resistance 30
Cable capacitance 10 nF
Operation time (reset button) 240 ms
Weight Depending on protective field height (see page 82)
17)
As per IEC 61131C2.
18)
Applies to the voltage range between –30 V and +30 V.