Operating instructions

Operating Instructions Chapter 11
C4000 Standard/Advanced
8009861/WA65/2012-06-12 © SICK AG • Industrial Safety Systems • Germany • All rights reserved 87
Subject to change without notice
Technical specifications
11.5.4 C4000 Standard/Advanced with M12 extension connection
Protective field height S [mm] Dimension L1 [mm] Dimension L2 [mm]
300 381 444
450 532 594
600 682 744
750 833 895
900 984 1046
1050 1134 1196
1200 1283 1346
1350 1435 1497
1500 1586 1649
1650 1736 1798
1800 1887 1949
Fig.
47
:
Dimensional drawing
C4000 Standard/Advanced
with M12 extension
connection, sender.
Receiver, mirror image
Tab.
39
:
Dimensions
depending on the protective
field height, C4000
Standard/Advanced with
M12 extension connection
Sliding nut groove
for side mounting
14
6
10.5
2.2
1
3.5
Socket according to DIN
43
651 (M12
×
7 + FE)
22.4
48
S
Plug according to DIN 43
651
(
M
26
×
11
+
FE)
40
20
L1
L2
56.3
27
Approx. 70
(connector range)
66
Cable plug M12
×
7
+
FE
with crimp contacts
Approx. 100 (connector
range)
75
Approx. 140 (connector
range)
100
Cable sockets
M
26
×
11
+
FE with crimp
contacts
65
50
Approx. 100
(connector range)