Owner manual

AR-5127 SIMULATION 8 - 7
Operation/procedure
[Selection 1]
Select with the 10-key.
[Selection 2]
(Input/Selection screen)
Operation/procedure
The operating states of the sensor and the detector are displayed.
The active sensors and detectors are highlighted.
Note: Execution is possible only when the option cassette is installed.
Operation/procedure
Select the load to check with the 10-key.
During execution of load operation, [EXEC] is highlighted.
Pressing the [BACK] key under this state interrupts the operation.
The motor for 10sec, the solenoid ON for 500msec, OFF for 500msec.
The lift-up motor operates only when the tray is opened. (20 times)
Note: Execution is possible only when the option cassette is installed.
Operation/procedure
The LCD is displayed as follows. (All LED’s are ON.)
3-11
Purpose Operation test/check
Function
(Purpose)
Used to check the operation of the shifter.
Item Operation
(Initial screen) (Executing screen)
1:F-R
Reciprocating operation
2:HP CHECK
Home position check
SFTHP:
Shifter home position (At detection, highlighted)
[
] key Shifts the position toward R side by the specified steps.
[
] key Shifts the position toward F side by the specified steps.
[
] key Shifts to the home position.
4
4-2
Purpose Operation test/check
Function
(Purpose)
Used to check the operation of sensor and detector in
the option tray and the related circuit.
Section Paper feed
Item Operation
PED2
2nd cassette paper empty sensor
LUD2
2nd cassette paper upper limit detection sensor
PFD2
2nd cassette paper pass sensor
CD2
2nd cassette empty sensor
PED3
3rd cassette paper empty sensor
LUD3
3rd cassette paper upper limit detection sensor
PFD3
3rd cassette paper pass sensor
CD3
3rd cassette empty sensor
PED4
4th cassette paper empty sensor
LUD4
4th cassette paper upper limit detection sensor
PFD4
4th cassette paper pass sensor
CD4
4th cassette empty sensor
DSWR3
3rd cassette right door detection sensor
DSWR2
2nd cassette right door detection sensor
DSWR4
4th cassette right door detection sensor
Sim3-11 SHIFTER CHK
1:F-R
2:HP CHECK
1
Sim3-11 SHIFTER CHK
1:F-R
2:HP CHECK
EXEC 1
Sim3-11 SHIFTER CHK
SFTHP
[ ]:R [ ]:HP [ ]:F
Sim4-2 SENSOR CHECK
PED2 LUD2 PFD2 CD2
PED3 LUD3 PFD3 CD3
PED4 LUD4 PFD4 CD4
DSWR2 DSWR3 DSWR4
4-3
Purpose Operation test/check
Function
(Purpose)
Used to check the operation of the load in the option
tray and the control circuit.
Section Paper feed
Item Operation
(Initial screen) (Executing screen)
1:LUM2
2nd cassette lift-up motor
2:CPFC2
2nd cassette pick-up solenoid
3:CPFS2
2nd cassette paper feed clutch
4:TRC2
2nd cassette transport roller clutch
5:DM
2nd cassette paper transport motor (3rd cassette paper
transport motor)
6:LUM3
3rd cassette lift-up motor
7:CPFC3
3rd cassette pick-up solenoid
8:CPFS3
3rd cassette paper feed clutch
9:TRC3
3rd cassette transport roller clutch
10:LUM4
4th cassette lift-up motor
11:CPFC4
4th cassette pick-up solenoid
12:CPFS4
4th cassette paper feed clutch
5
5-1
Purpose Operation test/check
Function
(Purpose)
Used to check the operation of the display, LCD in the
operation panel, and control circuit.
Section Operation (screen/operation)
Item Operation
(Initial screen)
With the upper half section highlighted,
contrast changes "Standard
MAX
MIN." in
every 2sec.
(6 sec later)
With the lower half section highlighted, contrast
changes "Standard
MAX
MIN." in every
2sec.
(6 sec later)
The back light changes in the sequence of
"OFF
Red
Yellow
Green" every 2
seconds.
Sim4-3 OUTPUT CHECK
1:LUM2 4:TRC2
2:CPFC2 5:DM
3:CPFS2 6:LUM3
1/2 EXEC
Sim4-3 OUTPUT CHECK
7:CPFC3 10:LUM4
8:CPFS3 11:CPFC4
9:TRC3 12:CPFS4
2/2 EXEC 8
Sim5-1 LCD/LED CHK.
Sim5-1 LCD/LED CHK.
Sim5-1 LCD/LED CHK.