Service manual

29
DT-100
Ref No.
1
R905
2
--
3
IC7707
4
IC7704
5
IC7701
1
2
 
Adjustment jig (resistance load 25Ω)
Connecting cord (conversion cable)
Part name
Part name
Part code
Part code
PWM controller
RR-FZA002WJZZ
DUNTKD148WEF0
RH-iXB458WJZZ
Manufacturer
RUNTZA018WJZZ
Asahi Communication
QCNW-E007WJZZ
SMK
VHITA78L05F-1Y
VHIM51995AF-1Y
Cement resistor
Control PWB
Ballast microprocessor
5V regulator
Ballast Unit
Lamp Cable
(QCNW-D573WJQZ)
Adjustment Jig
(RU NTZA 018WJZZ)
C onnecting C ord
(Q C N W -E007WJZZ)
Projector
TP1
TP2
−
+
[Adjustment of ballast unit output power (lamp power)]
1. List of parts requiring adjustment
When replacing the following parts, adjust the ballast unit output power (lamp power).
2. Adjustment jigs
The following jigs are required for adjusting the ballast unit output power (lamp power).
3. Ballast unit output power (lamp power) adjustment method
Adjust the ballast unit output power (lamp power) in the following method.
[Adjustment method]
(1)Unplug the ballast unit lamp cable(QCNW-D573WJQZ) of the projector from 
the lamp and connect the cable to the connecting cord (QCNW-E007WJZZ).
(2) Connect the connecting cord (QCNW-E007WJZZ) to the adjustment jig 
(RUNTZA018WJZZ).
(3) Connect TP1 of the adjustment jig (RUNTZA018WJZZ) to the negative terminal of the 
tester and TP2 to the positive terminal.
(4) Turn on the projector.
(5) Age the projector for 60 seconds or more.
(6) Adjust the volume resistor (R7728) of the ballast control PWB (DUNTKD148WEF0) so 
that the voltage of the tester reaches 83± 0.5 V.
Adjustment value: 83± 0.5 V
[Cautions]
(1) Caution for electric shock: Do not touch the test points TP1 and TP2 of the adjustment 
jig when supplying power since a high voltage and large current is applied to them.
(2) Caution for heat: Be careful that the resistance load of the adjustment jig produces a high 
temperature when supplying power.
(3) Connection of the lamp cable: Check that the lamp cable and connecting cord (QCNW-E
007WJZZ) are connected securely.
Poor connection may cause smoking or ignition due to arc discharge.
[Setting method]
Tester
(Voltage)