Instruction manual

43
8.6 Adjustment of Vertical Angle 0 Datum
If when measuring the vertical angle of target A at telescope position normal
(direct) and reverse settings, the amount of normal and reverse measure-
ments combined is other than 360° (ZENITH-0), half of the difference from
360° is the error amount from corrected 0 setting. Carry out adjustment. As
adjustment for vertical angle 0 setting is the criteria for determining instru-
ment coordinate origin, use special care for adjustment.
1
Level the instrument properly with the plate level.
2
While pressing the [0SET]key, turn power switch ON.
3
Collimate target A from the telescope properly in normal setting.
4
Press the [0SET] key.
5
Collimate target A in reverse telescope setting.
6
Press the [0SET]key.
Measured value is set and carry out normal angle measurement.
7
Turn the power switch off.
Any misoperating and error code display appears. Repeat the
above procedure from the start.
Check that the total amount of normal and reverse angular
travel is 360°
collimating the target A by normal and reverse
positions.
V STEP-1
V STEP-2
SET